Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Elevated values of cardiac troponin I in patients with coronary disease verified with computed tomography coronary angiography, preliminary results (CROSBI ID 731527)

Prilog sa skupa u časopisu | sažetak izlaganja sa skupa | međunarodna recenzija

Svaguša, Tomo ; Manola, Šime ; Žarak, Marko ; Vujević, Filip ; Pfeifer, Luka ; Prgomet, Luka ; Vučko, Ivo ; Mixich, Renee ; Jurković Dubravčić, Nikolina ; Rudan, Diana Elevated values of cardiac troponin I in patients with coronary disease verified with computed tomography coronary angiography, preliminary results // Cardiologia Croatica. 2022. str. 243-243 doi: 10.15836/ccar2022.243

Podaci o odgovornosti

Svaguša, Tomo ; Manola, Šime ; Žarak, Marko ; Vujević, Filip ; Pfeifer, Luka ; Prgomet, Luka ; Vučko, Ivo ; Mixich, Renee ; Jurković Dubravčić, Nikolina ; Rudan, Diana

engleski

Elevated values of cardiac troponin I in patients with coronary disease verified with computed tomography coronary angiography, preliminary results

Introduction: Cardiac troponin I (cTnI) has been shown to have predictive value for cardiovascular incidents in the general population. With the newest 5th generation cTn tests it is possible to measure its concentration in most of population (1, 2). The aim of this study is to investigate the correlation between plasma levels of cTnI measured by Beckman Coulter high sensitivity test and presence of cardiac pathology (mostly coronary artery disease and heart failure). Patients and Methods: All 100 patients who underwent computed tomography coronary angiography in Dubrava University Hospital from 14th February until 28th June 2022 were included in study. 75 patients had no cardiac pathology (median age 58 y [IQR 48-85], 49% were male) and 25 patients had heart failure or known/new verified coronary artery disease (median age 63 y [IQR 57-72], 60% were male). cTnI was measured using chemiluminescent high sensitivity Beckman Coulter cTnI test. Results: For statistical analysis, we used the non- parametric Mann Whitney U test. The median value of cTnI concentration in the population of patients without verified cardiac pathology is 3.9 ng/L [IQR 2.9-5.15], while the median value of cTnI in patients with heart disease is 7.4 ng/L [IQR 4.2-11.5] P=0.2113. Conclusion: Although cTnI values are slightly higher in patients with cardiac pathology compared to the control group, the difference is not statistically significant. The above can be explained by the good control of cardiovascular risk factors, which is why the most of concentration of cTnI in heart disease group overlaps with the values in the control group. cTnI could be a good screening marker for patients with increased cardiovascular risk.

coronary artery disease ; computed tomography coronary angiography ; cardiac troponin I

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

243-243.

2022.

nije evidentirano

objavljeno

10.15836/ccar2022.243

Podaci o matičnoj publikaciji

Cardiologia Croatica

Medicinska naklada

1848-543X

Podaci o skupu

14. kongres Hrvatskoga kardiološkog društva ; 9. kongres Hrvatske udruge kardioloških medicinskih sestara = 14th Congress of the Croatian Cardiac Society ; 9th Congress of the Croatian Association of Cardiology Nurses

poster

24.11.2022-27.11.2022

Zagreb, Hrvatska

Povezanost rada

Temeljne medicinske znanosti

Poveznice