Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Design of flow injection spectrophotometric system for penicillamine determination in pharmaceutical formulations (CROSBI ID 731472)

Prilog sa skupa u zborniku | sažetak izlaganja sa skupa | međunarodna recenzija

Kukoc-Modun, Lea ; Biocic, Maja ; Dugeč, Josipa ; Radić, Njegomir Design of flow injection spectrophotometric system for penicillamine determination in pharmaceutical formulations // Book of abstracts Flow Analysis XV / Kozak, Joanna ; Telk, Anna ; Woźniakiewicz, Aneta et al. (ur.). Krakov: Department of Analytical Chemistry, Faculty of Chemistry, Jagiellonian University in Krakow, Krakow 2022, 2022. str. 135-135

Podaci o odgovornosti

Kukoc-Modun, Lea ; Biocic, Maja ; Dugeč, Josipa ; Radić, Njegomir

engleski

Design of flow injection spectrophotometric system for penicillamine determination in pharmaceutical formulations

A new, sensitive, rapid, and precise flow injection spectrophotometric method for the determination of penicillamine (PEN) in pharmaceutical formulations has been developed and validated. Penicillamine is a synthetic amino acid that contains an additional SH group and can form non-toxic, water-soluble chelates with heavy metals, which are then excreted in the urine. PEN was the first chelator used for Wilson's disease, and it can also be used for lead, mercury and arsenic poisoning. The method is based on a fast one-step redox reaction wherein PEN reduces the Cu(II)-bathocuproine complex to the Cu(I)-bathocuproine complex, which exhibits absorption maxima at 483 nm. Therefore, a simple two stream single reagent manifold was used. By decreasing the inner volume of the flow cell (from 160 μL to 30 μL), the miniaturization of other parts of the manifold was enabled. Therefore the sensitivity of PEN determination was advanced, and sampling frequency increased. Optimization of experimental conditions and manifold parameters was carried out through the univariate method. The reagent, prepared in acetic buffer solution (pH = 5), was merged with a sample (200 μL) and injected into a carrier stream of distilled water at a confluence point, where streams combined. The flow rate of the carrier stream was 6 mL/min, and the reagent was pumped at the rate of 2 mL/min. The reaction coil, 30 cm long and 0.8 mm I.D. (volume 150 μL), was kept at room temperature. Since the flow rate through the reactor was 133 μL/sec, the incubation time was just over a second, yet sufficiently long for the reaction to reach a steady state. A linear calibration curve was established in a concentration range of PEN from 2×10−7 to 4×10−5 mol L−1 with regression equation y = 8.48×103 x – 0.0011 (R2 = 0.9996). The novel FI-method is sensitive enough to enable LOD below 8 ppb of PEN at a sampling rate of 180 s/hr without expensive instruments. In addition, method is precise (RSD 0.9%, n = 100) and accurate (recovery in the range from 98.7% to 101.6%). The proposed method can be applied for the determination of PEN in pharmaceutical formulations since usual excipients and other present active substances in pharmaceuticals do not interfere.

penicillamine ; flow injection analysis ; pharmaceutical formulations

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

135-135.

2022.

objavljeno

Podaci o matičnoj publikaciji

Book of abstracts Flow Analysis XV

Kozak, Joanna ; Telk, Anna ; Woźniakiewicz, Aneta ; Paluch, Justyna

Krakov: Department of Analytical Chemistry, Faculty of Chemistry, Jagiellonian University in Krakow, Krakow 2022

978-83-963504-1-1

Podaci o skupu

15th International Symposium on Numerical Analysis of Fluid Flow, Heat and Mass Transfer

poster

26.06.2022-01.07.2022

Kraków, Poljska

Povezanost rada

Kemija