Calculated Epithelial/Absorbed Power Density for Exposure from Antennas at 10–90 GHz: Intercomparison Study Using a Planar Skin Model (CROSBI ID 319717)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Li, Kun ; Kodera, Sachiko ; Poljak, Dragan ; Diao, Yinliang ; Sasaki, Kensuke ; Šušnjara, Anna ; Prokop, Alexander ; Taguchi, Kenji ; Xi, Jingtian ; Zhang, Shuai et al. Calculated Epithelial/Absorbed Power Density for Exposure from Antennas at 10–90 GHz: Intercomparison Study Using a Planar Skin Model // IEEE access, 11 (2023), 7420-7435. doi: 10.1109/ACCESS.2023.3238582

Podaci o odgovornosti

Li, Kun ; Kodera, Sachiko ; Poljak, Dragan ; Diao, Yinliang ; Sasaki, Kensuke ; Šušnjara, Anna ; Prokop, Alexander ; Taguchi, Kenji ; Xi, Jingtian ; Zhang, Shuai ; Yao, Ming ; Sacco, Giulia ; Zhadobov, Maxim ; El Hajj, Walid ; Hirata, Akimasa

engleski

Calculated Epithelial/Absorbed Power Density for Exposure from Antennas at 10–90 GHz: Intercomparison Study Using a Planar Skin Model

International organizations have collaborated to revise standards and guidelines for human protection from exposure to electromagnetic fields. In the frequency range of 6–300 GHz, the permissible spatially averaged epithelial/absorbed power density, which is primarily derived from thermal modeling, is considered the basic restriction. However, for the averaging methods of the epithelial/absorbed power density inside human tissues, only a few groups have presented calculated results obtained using different exposure conditions and numerical methods. Because experimental validation is extremely difficult in this frequency range, this paper presents the first intercomparison study of the calculated epithelial/absorbed power density inside a human body model exposed to different frequency sources ranging from 10–90 GHz. This intercomparison aims to clarify the difference in the calculated results caused by different numerical electromagnetic methods in dosimetry analysis from 11 research groups using planar skin models. To reduce the comparison variances caused by various key parameters, computational conditions (e.g., the antenna type, dimensions, and dielectric properties of the skin models) were unified. The results indicate that the maximum relative standard deviation (RSD) of the peak spatially averaged epithelial/absorbed power densities for one- and three-layer skin models are less than 17.49% and 17.39%, respectively, when using a dipole antenna as the exposure source. For the dipole array antenna, the corresponding maximum RSD increases to 32.49% and 42.55%, respectively. Under the considered exposure scenarios, the RSD in the spatially averaged epithelial/absorbed power densities decrease from 42.55% to 16.7% when the frequency is increased from 10–90 GHz. Furthermore, the deviation from the two equations recommended by the exposure guidelines for deriving the spatially averaged epithelial/absorptive power density is mostly within 1 dB. The fair agreement in the intercomparison results demonstrates that the variances of the spatially averaged epithelial/absorbed power densities calculated using planar skin models are marginal.

dosimetry modeling ; electromagnetic field ; epithelial/absorbed power density ; millimeter wave exposure ; standardization ; skin model