Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

A Review of Testing Procedures for Proton Exchange Membrane Electrolyzer Degradation (CROSBI ID 318918)

Prilog u časopisu | pregledni rad (znanstveni) | međunarodna recenzija

Tomić, Andrej Zvonimir ; Pivac, Ivan ; Barbir, Frano A Review of Testing Procedures for Proton Exchange Membrane Electrolyzer Degradation // Journal of power sources, 557 (2023), 232569, 21. doi: 10.1016/j.jpowsour.2022.232569

Podaci o odgovornosti

Tomić, Andrej Zvonimir ; Pivac, Ivan ; Barbir, Frano

engleski

A Review of Testing Procedures for Proton Exchange Membrane Electrolyzer Degradation

Durability of electrolyzers is one of the main challenges for their widespread commercialization, although many commercial PEM electrolyzer manufacturers claim durability up to 30, 000 h or even longer. Nevertheless, their degradation processes are increasingly investigated. There is a need to promptly diagnose degradation causes by monitoring the resulting performance decay. However, a wide spectrum of procedures for degradation testing makes it difficult to compare the obtained results, thus makes their practical application unsuitable. In order to systemize the proposed testing procedures, an overview of investigations that include PEM electrolyzer degradation testing is presented here, together with a comparative analysis and a critical review. The reviewed papers are grouped in accordance to whether the degradation tests were performed under constant or dynamic operating conditions. In addition, the review includes the advances and perspectives in accelerated test development. It was noticed that incomplete or inadequate membrane initial conditioning or activation affects the obtained results and, thus, the extracted conclusions. Therefore, before conducting any relevant degradation test, it is necessary first to define and carry out a suitable activation procedure, in order to compare the results of different degradation tests and reach the correct conclusions, which should be the subject of further research.

PEM electrolyzer ; Degradation test protocols ; Testing procedures ; Accelerated stress tests ; Constant operating conditions ; Dynamic operating conditions

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

557

2023.

232569

21

objavljeno

0378-7753

1873-2755

10.1016/j.jpowsour.2022.232569

Povezanost rada

Kemijsko inženjerstvo, Strojarstvo

Poveznice
Indeksiranost