Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Comparison of electrocoagulation coupled with synthetic zeolite, ultrasound and two steps electrocoagulation (CROSBI ID 318904)

Prilog u časopisu | izvorni znanstveni rad

Vukojević Medvidović, Nediljka ; Vrsalović, Ladislav ; Svilović, Sandra ; Cestarić, Mirjana Comparison of electrocoagulation coupled with synthetic zeolite, ultrasound and two steps electrocoagulation // Journal of sustainable technologies and materials, 2 (2022), 3; 1-10. doi: 10.57131/jstm.2022.3.1

Podaci o odgovornosti

Vukojević Medvidović, Nediljka ; Vrsalović, Ladislav ; Svilović, Sandra ; Cestarić, Mirjana

engleski

Comparison of electrocoagulation coupled with synthetic zeolite, ultrasound and two steps electrocoagulation

Due to the very complex composition of leachate wastewater, combining two or more physical, chemical, or biological processes, carried out simultaneously or sequentially, is highly needed in order to obtain effluent suitable for further discharge into sewage. In this paper, electrocoagulation coupled with synthetic zeolite (EC-NaX), electrocoagulation coupled with ultrasound (EC-US), and two steps electrocoagulation (EC-1st and EC-2nd) were tested for compost leachate treatment, with very high initial organic loading and acidic pH. The comparison of each process was done in regard to the following parameters: pH, electrical conductivity and temperature change, removal percentage of chemical oxygen demand (COD), turbidity, total solids change, settling ability, and electrode consumption. Results highlight the EC-NaX as the best option for the treatment of compost leachate, due to the highest removal percentage of COD (51.91%), satisfactory removal percentage of turbidity (97%), good settling abilities, and lowest electrode consumption. However, the final COD values in the effluent are still significantly high for further discharge into sewage systems, thus additional treatment needs to be applied. Also, the final acidic pH, high values of electrical conductivity, and high temperature of effluent need to be solved in further treatment steps.

Al-electrode ; coupled electrocoagulation ; synthetic zeolite ; ultrasound ; two-step

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

2 (3)

2022.

1-10

objavljeno

2744-2640

2744-2659

10.57131/jstm.2022.3.1

Povezanost rada

Kemijsko inženjerstvo

Poveznice