Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Application of Electrocoagulation for Disinfection and Treatment of Water Contaminated With Arsenic and Chromium (CROSBI ID 730042)

Prilog sa skupa u zborniku | sažetak izlaganja sa skupa | međunarodna recenzija

Licht, Katarina ; Halkijević, Ivan ; Posavčić, Hana ; Nakić, Domagoj Application of Electrocoagulation for Disinfection and Treatment of Water Contaminated With Arsenic and Chromium // 9th International Conference Water for all / Habuda-Stanić, Mirna (ur.). Osijek, 2022. str. 21-28

Podaci o odgovornosti

Licht, Katarina ; Halkijević, Ivan ; Posavčić, Hana ; Nakić, Domagoj

engleski

Application of Electrocoagulation for Disinfection and Treatment of Water Contaminated With Arsenic and Chromium

Local water supply systems pose the greatest risk from a public health perspective because water is delivered to consumers without any treatment and often even without disinfection. The most common causes of contamination are microbiological contamination and elevated concentrations of heavy metals. Such water must be treated to be safe for human consumption. The most common water disinfection process used in drinking water treatment is disinfection with chlorine-based compounds. However, the by-products of the reaction of chlorine and organic matter are chlorinated hydrocarbons and nitrosamines, which can be extremely carcinogenic. The accumulation of these by-products along with the accumulation of heavy metals in the human body increases the risk of adverse effects on human health. Electrocoagulation (EC) is an alternative method of raw water treatment. Electrocoagulation uses an electric field and sacrificial electrodes to generate coagulants that separate, aggregate, and precipitate contaminants from the water. This method has proven successful in removing heavy metals from water, but also as a disinfection method. The objective of this study was to use EC to remove arsenic and chromium and to disinfect raw water enriched with Escherichia coli. The process took place in a batch reactor with 2 electrodes (1 anode and 1 cathode) at a voltage of 62 V. The efficiency of the process as a function of electrode material (Fe, Al, Cu and graphite) and treatment time was studied. With the exception of graphite, all electrodes showed 100% efficiency in the removal of As and Cr, while the disinfection efficiency varied.

water treatment, electrocoagulation, heavy metals, disinfection

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

21-28.

2022.

objavljeno

Podaci o matičnoj publikaciji

9th International Conference Water for all

Habuda-Stanić, Mirna

Osijek:

978-953-7005-85-6

Podaci o skupu

9. međunarodni znanstveno-stručni skup: Voda za sve = 9th International Scientific and Professional Conference: Water for all

predavanje

19.05.2022-20.05.2022

Osijek, Hrvatska

Povezanost rada

Građevinarstvo, Interdisciplinarne tehničke znanosti, Kemijsko inženjerstvo