Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Should the Application of Diode Laser Completely Replace Conventional Pulpotomy of Primary Teeth? (CROSBI ID 316593)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Šimunović, Luka ; Špiljak, Bruno ; Vranić, Lara ; Bašić, Rebecca ; Negovetić Vranić, Dubravka Should the Application of Diode Laser Completely Replace Conventional Pulpotomy of Primary Teeth? // Applied sciences (Basel), 12 (2022), 22; 1-13. doi: 10.3390/app122211667

Podaci o odgovornosti

Šimunović, Luka ; Špiljak, Bruno ; Vranić, Lara ; Bašić, Rebecca ; Negovetić Vranić, Dubravka

engleski

Should the Application of Diode Laser Completely Replace Conventional Pulpotomy of Primary Teeth?

Nowadays, the use of lasers in dental medicine has become an effective approach for numerous restorative and soft tissue therapeutic procedures. The use of different types of lasers depends on how the tissue interacts with the laser light and the purpose of treatment. Although some studies show the benefits of laser pulpotomy compared to the conventional method of pulpotomy, clinical studies are lacking. Moreover, the material used for a definitive restoration of endodontically treated primary teeth can also affect the outcome of the therapy. Therefore, this prospective study aimed to compare the clinical use of the diode laser and the conventional method of vital pulpotomy, as well as the influence of the material chosen for a definitive restoration for the outcome of the procedure. Patients were divided into two groups: conventional pulpotomy and 980 nm diode laser. Each group was then divided into two subgroups according to the type of material for the final restoration. By comparing the success of the therapy according to clinical parameters depending on the material of the final restoration, the advantage of the composite material compared to the glass ionomer cement was noticed at 6 months checkup (p = 0.045). A strong positive correlation between the quality of the final restoration according to the United States Public Health Service (USPHS) criteria and the success of the clinical parameters was found in all investigated time points. There is no statistically significant difference between the diode laser and the conventional pulpotomy, however, the choice and quality of the final restoration significantly contribute to the outcome of therapy

diode lasers ; endodontology ; primary teeth

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

12 (22)

2022.

1-13

objavljeno

2076-3417

10.3390/app122211667

Povezanost rada

Dentalna medicina

Poveznice
Indeksiranost