Đurin, Bojan ; Raič, Mirna ; Sušilović, Petra Application of the RAPS Method of Time Series Analysis to the Assessment of Grout Curtain Performance in Karst—A Case Study of the Hydro Energy Power Plant (HEPP) Mostar Dam in Bosnia and Herzegovina // Hydrology, 9 (2022), 11; 1-17. doi: 10.3390/hydrology9110192

Podaci o odgovornosti

Đurin, Bojan ; Raič, Mirna ; Sušilović, Petra

engleski

Application of the RAPS Method of Time Series Analysis to the Assessment of Grout Curtain Performance in Karst—A Case Study of the Hydro Energy Power Plant (HEPP) Mostar Dam in Bosnia and Herzegovina

Concerning the media’s properties, there is always a possibility of changing groundwater flow conditions surrounding hydroelectric power plants. Causes for such events could be natural or anthropogenic, which is, in many cases, not so obvious to determine. In addition, determining a period when changes in the groundwater flow occur is a complex task. All of the above mentioned are of crucial importance due to the operational work of hydropower plants, i.e., the optimization of the inflow and outflow of the water in the turbine, regardless of the hydropower plant type. All types listed require a particular approach for solving such issues. Rescaled Adjusted Partial Sums (RAPS) is an appropriate time-series analysis method. In this specific case, observed fluctuations in the time series of the groundwater levels could lead to conclusions about possible irregularities in the shallow as well as the deep zones of the underground water. The concept was shown in this paper in the example of the hydroelectric power plant Mostar dam in Bosnia and Herzegovina. It should be noted that the defined methodology was a novel procedure for analyzing and determining the pathways of the flow of groundwater in the surrounding hydropower plant dams. In other words, such analysis could be conducted without the need for complex and expensive drilling and geophysical surveys, tracing, and all other methods.

groundwater ; water levels ; hydroelectric power plant ; piezometer ; RAPS