Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Development of carbon paste electrode for the potentiometric determination of acebutolol (CROSBI ID 724459)

Prilog sa skupa u zborniku | sažetak izlaganja sa skupa | međunarodna recenzija

Radić, Josip ; Bralić, Marija ; Radan, Anđela ; Škutin, Lana ; Vučetić, Marija Development of carbon paste electrode for the potentiometric determination of acebutolol // 19. Ružičkini dani "Danas znanost-sutra industrija" / Babić, Jurislav (ur.). Osijek : Zagreb: Prehrambeno tehnološki fakultet Sveučilišta Josipa Jurja Strossmayera u Osijeku ; Hrvatsko društvo kemijskih inženjera i tehnologa (HDKI), 2022. str. 45-45

Podaci o odgovornosti

Radić, Josip ; Bralić, Marija ; Radan, Anđela ; Škutin, Lana ; Vučetić, Marija

engleski

Development of carbon paste electrode for the potentiometric determination of acebutolol

Electrodes based on carbon paste are often used in electrochemical measurements due to their good physical and chemical properties.[1] In this work carbon paste electrodes (CPEs) for the potentiometric determination of the acebutolol hydrochloride, cardiovascular drug from the family of beta blockers, were prepared. The design and manufacture of the working electrode body was previously reported.[2] Some of the most frequently tested binders in the last ten years, such as: dibutyl phthalate, bis(2-ethylhexyl)phthalate, paraffin oil, tris(2-ethylhexyl)phosphate, 2-nitrophenyl-octyl-ether and bis(2-ethylhexyl) adipate were used. In order to improve the sensitivity, the CPE were modified by the addition of previously precipitated ion association complexes (IAC) and various ion additives. All measurements were performed in the concentration range of working solutions of acebutolol from 3.16×10−6 M to 3.16×10−3 M in an acetate buffer with a pH value of 5.0. Although this research gave promising results, prepared CPEs showed worse preliminary response characteristics than CPE for acebutolol determination previously reported.[3] In further research, emphasis is going to be placed on the incorporation of different nanomaterials into the paste, especially those made of carbon materials.

carbon paste electrodes, potentiometry, acebutolol

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

45-45.

2022.

objavljeno

Podaci o matičnoj publikaciji

Babić, Jurislav

Osijek : Zagreb: Prehrambeno tehnološki fakultet Sveučilišta Josipa Jurja Strossmayera u Osijeku ; Hrvatsko društvo kemijskih inženjera i tehnologa (HDKI)

2718-6040

Podaci o skupu

17. Ružičkini dani "Danas znanost-sutra industrija"

poster

21.09.2022-23.09.2022

Vukovar, Hrvatska

Povezanost rada

Kemija