Calibration Approach for Gaseous Oxidized Mercury Based on Nonthermal Plasma Oxidation of Elemental Mercury (CROSBI ID 314813)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Gačnik, Jan ; Živković, Igor ; Ribeiro Guevara, Sergio ; Kotnik, Jože ; Berisha, Sabina ; Vijayakumaran Nair, Sreekanth ; Jurov, Andrea ; Cvelbar, Uroš ; Horvat, Milena Calibration Approach for Gaseous Oxidized Mercury Based on Nonthermal Plasma Oxidation of Elemental Mercury // Analytical chemistry, 94 (2022), 23; 8234-8240. doi: 10.1021/acs.analchem.2c00260

Podaci o odgovornosti

Gačnik, Jan ; Živković, Igor ; Ribeiro Guevara, Sergio ; Kotnik, Jože ; Berisha, Sabina ; Vijayakumaran Nair, Sreekanth ; Jurov, Andrea ; Cvelbar, Uroš ; Horvat, Milena

engleski

Calibration Approach for Gaseous Oxidized Mercury Based on Nonthermal Plasma Oxidation of Elemental Mercury

Atmospheric mercury measurements carried out in the recent decades have been a subject of bias largely due to insufficient consideration of metrological traceability and associated measurement uncertainty, which are ultimately needed for the demonstration of comparability of the measurement results. This is particularly challenging for gaseous HgII species, which are reactive and their ambient concentrations are very low, causing difficulties in proper sampling and calibration. Calibration for atmospheric HgII exists, but barriers to reliable calibration are most evident at ambient HgII concentration levels. We present a calibration of HgII species based on nonthermal plasma oxidation of Hg0 to HgII. Hg0 was produced by quantitative reduction of HgII in aqueous solution by SnCl2 and aeration. The generated Hg0 in a stream of He and traces of reaction gas (O2, Cl2, or Br2) was then oxidized to different HgII species by nonthermal plasma. A highly sensitive 197Hg radiotracer was used to evaluate the oxidation efficiency. Nonthermal plasma oxidation efficiencies with corresponding expanded standard uncertainty values were 100.5 ± 4.7% (k = 2) for 100 pg of HgO, 96.8 ± 7.3% (k = 2) for 250 pg of HgCl2, and 77.3 ± 9.4% (k = 2) for 250 pg of HgBr2. The presence of HgO, HgCl2, and HgBr2 was confirmed by temperature-programmed desorption quadrupole mass spectrometry (TPD-QMS). This work demonstrates the potential for nonthermal plasma oxidation to generate reliable and repeatable amounts of HgII compounds for routine calibration of ambient air measurement instrumentation.

gaseous oxidized mercury, nonthermal plasma, elemental mercury, mercury

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

94 (23)

2022.

8234-8240

objavljeno

0003-2700

0003-2700

10.1021/acs.analchem.2c00260

Povezanost rada

Fizika, Interdisciplinarne prirodne znanosti, Kemija