Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

An ion beam spot size monitor based on a nano- machined Si photodiode probed by means of the ion beam induced charge technique (CROSBI ID 314630)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Andrini, G. ; Nieto Hernández, E. ; Provatas, Georgios ; Brajković, Marko ; Crnjac, Andreo ; Tchernij, S. Ditalia ; Forneris, J. ; Rigato, V. ; Campostrini, M. ; Siketić, Zdravko et al. An ion beam spot size monitor based on a nano- machined Si photodiode probed by means of the ion beam induced charge technique // Vacuum, 205 (2022), 111392, 8. doi: 10.1016/j.vacuum.2022.111392

Podaci o odgovornosti

Andrini, G. ; Nieto Hernández, E. ; Provatas, Georgios ; Brajković, Marko ; Crnjac, Andreo ; Tchernij, S. Ditalia ; Forneris, J. ; Rigato, V. ; Campostrini, M. ; Siketić, Zdravko ; Jakšić, Milko ; Vittone, E.

engleski

An ion beam spot size monitor based on a nano- machined Si photodiode probed by means of the ion beam induced charge technique

In this work the utilization of the Ion Beam Induced Charge (IBIC) technique is explored to assess the resolution a 2 MeV Li + ion microbeam raster scanning a micrometer-sized FIB-machined hollows in a silicon photodiode. The analysis of the maps crossing the FIB machined structures evidenced a drop in charge collection efficiency across the perimeter of the hollows combined with a significant recovery of the signal amplitude at the center of the microstructures, thus forming a micrometer-sized feature which can be exploited to estimate the resolution of the probing beam. The results were interpreted according to numerical simulations based on the Shockley-Ramo-Gunn as originating from a FIB-induced surface space charge density. These results offered additional information with respect to what achievable by a confocal photocurrent microscopy analysis of the same device, due to the significantly shorter focal depth of the latter with respect to the probing ion beam. This study suggests the viability of an effective method to evaluate of the resolution of ion microbeams in processes and experiments, which could be beneficial in emerging fields (deterministic implantation, micro-radiobiology, ion lithography) demanding beam spot sizes below the micrometer scale.

Charge collection efficiency ; Silicon ; Ion beam induced charge (IBIC) ; Ion microbeam

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

205

2022.

111392

8

objavljeno

0042-207X

10.1016/j.vacuum.2022.111392

Povezanost rada

Fizika

Poveznice
Indeksiranost