Comparison of the conventional loading case on femur with Pauwels type III fracture with force reduction loading: A finite element study (CROSBI ID 723808)
Prilog sa skupa u zborniku | prošireni sažetak izlaganja sa skupa | međunarodna recenzija
Podaci o odgovornosti
Adamović, Petra ; Bočkaj, Nina, Jurčević Lulić, Tanja ; Kodvanj, Janoš
engleski
Comparison of the conventional loading case on femur with Pauwels type III fracture with force reduction loading: A finite element study
The application of finite element method in interdisciplinary sciences such as biomedical engineering has been quite common in the last few decades. Treatment of intracapsular hip fractures such as femoral neck fracture of Pauwels type III still remains a challenging matter, given the fact that this disease nowadays involves more than 50% of all proximal femoral fractures. While creating an internal fixation device for that matter, it is necessary to conduct experimental tests. The goal of simulations is to select the crucial device test loads and setups, i.e., to reduce the cost and time consumption of the tests. While most authors use a very primitive form of model loading in their simulations, this study uses two types of femur’s loading cases (climbing stair and walking) and compares two mechanically equivalent force loadings with their amounts.
Pauwels type III ; finite element method ; force reduction ; inverted triangle configuration
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
Podaci o prilogu
81-82.
2022.
objavljeno
Podaci o matičnoj publikaciji
10th International Congress of Croatian Society of Mechanics - Book of Abstracts
Skozrit, Ivica ; Sorić, Jurica ; Tonković, Zdenko
Pula: Sveučilišna tiskara
2584-7716
Podaci o skupu
10th International Congress of Croatian Society of Mechanic (ICCSM 2022)
predavanje
28.09.2022-30.09.2022
Pula, Hrvatska