Mehaničke značajke polilaktične kiseline (PLA) u izradi individualizirane biorazgradive augmentacijske mrežice - IBAM (CROSBI ID 723608)

Prilog sa skupa u časopisu | sažetak izlaganja sa skupa | međunarodna recenzija

Prpić, Vladimir ; Bjelica, Roko ; Drvar, Nenad ; Gabrić, Dragana ; Ćatić, Amir Mechanical characteristics of polylactic acid (PLA) in the fabrication process of individualized biodegradable augmentation scaffold – IBAM / Mehaničke značajke polilaktične kiseline (PLA) u izradi individualizirane biorazgradive augmentacijske mrežice - IBAM // Acta stomatologica Croatica, 56, 2 / Salarić, Ivan ; Brajdić, Davor (ur.). 2022. str. 330-330

Podaci o odgovornosti

Prpić, Vladimir ; Bjelica, Roko ; Drvar, Nenad ; Gabrić, Dragana ; Ćatić, Amir

hrvatski

Mehaničke značajke polilaktične kiseline (PLA) u izradi individualizirane biorazgradive augmentacijske mrežice - IBAM

Introduction: Various techniques have been developed for 3D reconstruction of the lost bone tissue, with currently the most widely used being titanium mesh replacement, the Khoury technique, and the distraction osteogenesis. All three techniques have significant disadvantages, narrow indication, and require exceptional operator skill. IBAM scaffold is made of biodegradable material, provide space for the formation of new bone tissue, and have the ability to be built into 3D complex individualized shapes. Simple individualized fabrication, biocompatibility, and planned biodegradability are the properties due to which PLA has found its application in tissue engineering. Materials and methods: In order to optimize the shape and mechanical characteristics of the biodegradable scaffold, the mechanical properties of 3D printed specimens were tested by finite element analysis (FEA) with different print orientations - horizontal, lateral and vertical. Also, the flexural strength and impact strength of extruded PLA were tested on an Inspekt table 50 kN (Hegewald & Peschke Meß - und Prüftechnik GmbH). Results: The results of the FEA examination demonstrated higher values of tensile strength in the horizontal (32.98- 35.53 MPa) and the lateral positions (26.97-29.69 MPa) compared to the vertical position (4.43-14.20 MPa). The horizontal position of the specimens also demonstrated the highest values when testing flexural strength, while during the impact strength testing the horizontal (0.40 J) and lateral positions (0.41 J) demonstrated double the values of the vertical position (0.2 J). Specimens of all tested orientations showed similar hardness values after 60s. Conclusions: Based on the defined marginal loads of the model and the FEA, the results demonstrate that the planned arc geometry satisfies the criteria of the loads to which the scaffold will be exposed in the oral cavity. Mechanical properties of PLA meet the planned utilization of IBAM in computer-guided individualized bone augmentation.

scaffold ; dental implantology ; polylactic acid ; IBAM

nije evidentirano

engleski

Mechanical characteristics of polylactic acid (PLA) in the fabrication process of individualized biodegradable augmentation scaffold – IBAM

Introduction: Various techniques have been developed for 3D reconstruction of the lost bone tissue, with currently the most widely used being titanium mesh replacement, the Khoury technique, and the distraction osteogenesis. All three techniques have significant disadvantages, narrow indication, and require exceptional operator skill. IBAM scaffold is made of biodegradable material, provide space for the formation of new bone tissue, and have the ability to be built into 3D complex individualized shapes. Simple individualized fabrication, biocompatibility, and planned biodegradability are the properties due to which PLA has found its application in tissue engineering. Materials and methods: In order to optimize the shape and mechanical characteristics of the biodegradable scaffold, the mechanical properties of 3D printed specimens were tested by finite element analysis (FEA) with different print orientations - horizontal, lateral and vertical. Also, the flexural strength and impact strength of extruded PLA were tested on an Inspekt table 50 kN (Hegewald & Peschke Meß - und Prüftechnik GmbH). Results: The results of the FEA examination demonstrated higher values of tensile strength in the horizontal (32.98- 35.53 MPa) and the lateral positions (26.97-29.69 MPa) compared to the vertical position (4.43-14.20 MPa). The horizontal position of the specimens also demonstrated the highest values when testing flexural strength, while during the impact strength testing the horizontal (0.40 J) and lateral positions (0.41 J) demonstrated double the values of the vertical position (0.2 J). Specimens of all tested orientations showed similar hardness values after 60s. Conclusions: Based on the defined marginal loads of the model and the FEA, the results demonstrate that the planned arc geometry satisfies the criteria of the loads to which the scaffold will be exposed in the oral cavity. Mechanical properties of PLA meet the planned utilization of IBAM in computer-guided individualized bone augmentation.

scaffold ; dental implantology ; polylactic acid ; IBAM

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

330-330.

2022.

56 (2)

objavljeno

Podaci o matičnoj publikaciji

Salarić, Ivan ; Brajdić, Davor

Zagreb: Stomatolški fakultet Sveučilišta u Zagrebu

0001-7019

1846-0410

Podaci o skupu

9. Međunarodni kongres Hrvatskoga društva za dentalnu implantologiju Hrvatskoga liječničkog zbora

predavanje

01.04.2022-03.04.2022

Dubrovnik, Hrvatska ; Mlini, Hrvatska

Povezanost rada

Dentalna medicina

Indeksiranost