Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

Sustainability Improvement of Kazakh Chemical Industry via Process Integration: A Case Study of Calcium Chloride Production (CROSBI ID 313844)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Boldyryev, Stanislav ; Khussanov, Alisher ; Gorbunov, Kostyantyn ; Gorbunova, Olga ; Sustainability Improvement of Kazakh Chemical Industry via Process Integration: A Case Study of Calcium Chloride Production // Chemical engineering transactions, 76 (2019), 1231-1236. doi: 10.3303/CET1976206

Podaci o odgovornosti

Boldyryev, Stanislav ; Khussanov, Alisher ; Gorbunov, Kostyantyn ; Gorbunova, Olga ;

engleski

Sustainability Improvement of Kazakh Chemical Industry via Process Integration: A Case Study of Calcium Chloride Production

This work presents the analysis of the calcium chloride concentration unit to reduce energy consumption and harmful emissions. The concentration of the calcium chloride in the raw materials is 14 % (mass) and a concentrated solution has 35 % of CaCl2. Process Integration techniques were used for the analysis of the existing process to identify bottlenecks and disadvantages. A Pinch approach was executed to get real energy targets, energy gap and possible ways for process update. The authors proposed the solution for the process improvement using traced Grid Diagram and detailed simulation of the parameters of heat exchangers and evaporation units to get a feasible and economically beneficial retrofit. The representative case study of a Kazakh chemical factory was presented. There are some barriers to the development of the profitable and feasible solution, e.g. process constraints and limited performance of existing equipment. It forces developing a local methodology to apply the case study in an appropriate and most profitable way. The energy consumption of the inspected unit is 25 % higher than the target value. Nevertheless, the 1st feasible retrofit case with a detailed simulation of heat exchanger network parameters has only 17 % less energy consumption but, at the same time, the improved operating conditions of the evaporation unit were achieved. The 2nd retrofit option reduces the energy consumption by 22 % and more complicated network with additional operation changes was proposed. The results of this work may be used for the energy saving retrofit of the industrial evaporation units and decreasing the environmental impact of the chemical industry in Kazakhstan.

Process Integration ; Calcium Chloride ; Energy Saving ; Pinch Analysis ;

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

76

2019.

1231-1236

objavljeno

1974-9791

2283-9216

10.3303/CET1976206

Povezanost rada

Interdisciplinarne tehničke znanosti, Kemijsko inženjerstvo, Strojarstvo

Poveznice
Indeksiranost