Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Impact of cementless Zweymüller stem anteversion on resistance to periprosthetic fracture in total hip arthroplasty (CROSBI ID 313048)

Prilog u časopisu | izvorni znanstveni rad | domaća recenzija

Čengić, Tomislav ; Kodvanj, Janoš ; Smoljanović Tomislav ; Adamović, Petra ; Alerić, Andrija ; Bohaček, Ivan ; Milošević, Milan ; Sabalić, Srećko ; Delimar, Domagoj Impact of cementless Zweymüller stem anteversion on resistance to periprosthetic fracture in total hip arthroplasty // Acta clinica Croatica, 60 (2021), 3; 429-434. doi: 10.20471/acc.2021.60.03.13

Podaci o odgovornosti

Čengić, Tomislav ; Kodvanj, Janoš ; Smoljanović Tomislav ; Adamović, Petra ; Alerić, Andrija ; Bohaček, Ivan ; Milošević, Milan ; Sabalić, Srećko ; Delimar, Domagoj

engleski

Impact of cementless Zweymüller stem anteversion on resistance to periprosthetic fracture in total hip arthroplasty

Total hip arthroplasty implies proper orientation of both acetabular and femoral components with a range of 25-40° of combined anteversion. The aim of the study was to examine resistance to periprosthetic fracture of the axially loaded cross section rectangular femoral stem (Zweymüller) with respect to different degrees of anteversion, implanted in the artificial bone model, in laboratory conditions. Femoral bone models with implanted femoral stems were divided into 3 groups depending on the degree of stem anteversion (A, control group 13-17° ; B, stem retroverted 0°-4° ; and C, stem anteverted 26- 30°). The amount of axial load leading to periprosthetic fracture (PPFx) of the artificial bone model was determined experimentally for each construct. The results showed that the load at which the PPFx occurred significantly increased with the increase of the endoprosthesis anteversion angle. In our clinical practice, we are often unable to place the acetabular component in an ideal grade of anteversion for intraoperatively determined reasons. The results of this experimental study suggested that increasing rectangular femoral (Zweymüller) stem anteversion lowered the risk of PPFx. This study was limited by experimental design (laboratory conditions, artificial bone) and should be clinically verified.

total hip arthroplasty ; periprosthetic fracture ; artificial bone model

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

60 (3)

2021.

429-434

objavljeno

0353-9466

10.20471/acc.2021.60.03.13

Povezanost rada

Biotehnologija u biomedicini (prirodno područje, biomedicina i zdravstvo, biotehničko područje), Strojarstvo, Temeljne medicinske znanosti

Poveznice
Indeksiranost