Passive Night Cooling Potential in Office Buildings in Continental and Mediterranean Climate Zone in Croatia (CROSBI ID 312962)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Veršić, Zoran ; Binički, Marin ; Nosil Mešić, Mateja Passive Night Cooling Potential in Office Buildings in Continental and Mediterranean Climate Zone in Croatia // Buildings, 12 (2022), 8; 1207, 24. doi: 10.3390/buildings12081207

Podaci o odgovornosti

Veršić, Zoran ; Binički, Marin ; Nosil Mešić, Mateja

engleski

Passive Night Cooling Potential in Office Buildings in Continental and Mediterranean Climate Zone in Croatia

The envelope is one of the most important driving factors in the energy efficiency of buildings. Typical for office and commercial buildings, curtain wall facades allow solar heat gains to be used during the winter but can lead to difficulties in reducing the cooling load during summer. The cooling load is dominant in most building types in the temperate maritime climate, while in the temperate continental climate, it is dominant mainly in office and commercial buildings. The goal of this research was to determine the potential of night passive cooling in an office building model in the most populated urban areas in Croatia-Zagreb and Split, which are located in two different climate zones. Suitable to the climate on-site, an appropriate building envelope and various types of passive and mechanical ventilation systems were selected for each location and case. Additional factors included and analysed were climate conditions, heat gains, the heat accumulation of the building, night ventilation through openings, unwanted air infiltration, and cooling loads. Through a detailed description of the model, passive cooling potential calculations, and Computer Fluid Dynamics (CFD) simulations, the results showed a potential of up to 43.5% savings in the cooling energy need for the temperate continental climate and 32.2% in the temperate marine climate. It was found from the analysis that night ventilation is expected to cool down the building enough to delay a need for cooling by several hours and improve fresh air requirements, thus saving power for cooling, and effectively reducing the need for air conditioning.

cross ventilation ; cooling energy need ; night ventilation cooling ; passive cooling