Analysis of Temporal and Spatial Gradients at Pronouncedly Fluctuating Cooling Conditions
Realised cooling velocities of a probe (cylinder) at discrete points at its radius during cooling at pronouncedly fluctuating cooling conditions are presented. Submerging the probe into an air-corundum (Al2O3) particles fluidised system imposes the fluctuating cooling conditions. The particles have an average granulation of 95 mm ; the cylindrical probe diameter is 50 mm and its height 175 mm. The probe surface temperature and the temperature 1.5 mm beneath its surface are measured with built-in thermocouples. The thermocouples have a very high sensitivity, which enables temperature variation recording according to the cooling dynamics. The relevant cooling time is 125 seconds. The temperature changes in discrete points of the cylinder radius are determined by the control volume method. The calculation results indicate a shift of the maximum cooling velocity towards the cylinder interior.
cooling velocity; cylinder; fluidised bed; temperature field; temperature gradients