Antimicrobial Efficacy and Permeability of Various Sealing Materials in Two Different Types of Implant–Abutment Connections (CROSBI ID 312340)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Smojver, Igor ; Bjelica, Roko ; Vuletić, Marko ; Gerbl, Dražena ; Budimir, Ana ; Gabrić, Dragana Antimicrobial Efficacy and Permeability of Various Sealing Materials in Two Different Types of Implant–Abutment Connections // International journal of molecular sciences, 23 (2022), 14; 1422-0067, 14. doi: 10.3390/ijms23148031

Podaci o odgovornosti

Smojver, Igor ; Bjelica, Roko ; Vuletić, Marko ; Gerbl, Dražena ; Budimir, Ana ; Gabrić, Dragana

engleski

Antimicrobial Efficacy and Permeability of Various Sealing Materials in Two Different Types of Implant–Abutment Connections

The presence of a microgap along an implant– abutment connection (IAC) is considered the main disadvantage of two-piece implant systems. Its existence may lead to mechanical and biological complications. Different IAC designs have been developed to minimise microleakage through the microgap and to increase the stability of prosthodontic abutments. Furthermore, different sealing materials have appeared on the market to seal the gap at the IAC. The purpose of this study was to evaluate the antimicrobial efficacy and permeability of different materials designed to seal the microgap, and their behaviour in conical and straight types of internal IACs. One hundred dental implants with original prosthodontic abutments were divided into two groups of fifty implants according to the type of IAC. Three different sealing materials (GapSeal, Flow.sil, and Oxysafe gel) were applied in the test subgroups. The contamination of implant–abutment assemblies was performed by a joint suspension containing Candida albicans and Staphylococcus aureus. It was concluded that the IAC type had no significant influence on microleakage regarding microbial infection. No significant difference was found between the various sealing agents. Only one sealing agent (GapSeal) was found to significantly prevent microleakage. A complete hermetic seal was not achieved with any of the sealing agents tested in this study.

dental implant–abutment design ; peri-implantitis ; microbial colony count ; candida albicans ; staphylococcus aureus

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

23 (14)

2022.

1422-0067

14

objavljeno

1422-0067

10.3390/ijms23148031