Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

The repeatability of standard cranial measurements on dry bones and MSCT images (CROSBI ID 312301)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Jerković, Ivan ; Bašić, Željana ; Bareša, Tina ; Krešić, Elvira ; Adamić Hadžić, Anita ; Dolić, Krešimir ; Ćavar Borić, Marija ; Budimir Mršić, Danijela ; Čavka, Mislav ; Šlaus, Mario et al. The repeatability of standard cranial measurements on dry bones and MSCT images // Journal of forensic sciences, 67 (2022), 5; 1938-1947. doi: 10.1111/1556-4029.15100

Podaci o odgovornosti

Jerković, Ivan ; Bašić, Željana ; Bareša, Tina ; Krešić, Elvira ; Adamić Hadžić, Anita ; Dolić, Krešimir ; Ćavar Borić, Marija ; Budimir Mršić, Danijela ; Čavka, Mislav ; Šlaus, Mario ; Primorac, Dragan ; Anđelinović, Šimun ; Kružić, Ivana

engleski

The repeatability of standard cranial measurements on dry bones and MSCT images

This study examined if the cranial measurements from Data Collection Procedures for Forensic Skeletal Material 2.0 are repeatable when measured in dry bones and MSCT images and if the virtual measurements correspond to the physical ones. The sample included 33 dry crania imaged by MSCT. Two observers measured dry bones, two placed landmarks on 2D and 3D MSCT reconstructions, and one conducted measurements/landmarking on both media. One of the observers for each media repeated the measurements. Technical and relative technical error of measurement (TEM and rTEM) and percentage differences were calculated to examine the repeatability of measurements and compare measuring modalities. Intraobserver rTEM was above 1.5% for six bone measurements: FOB, ZOB, OBB, NLH, DKB, MDH (1.51%–4.87%) and for seven MSCT measurements: OBH, FOB, OBB, MDH, NLB, ZOB, DKB (1.57%–5.55%). The interobserver rTEM was above the acceptable level (>2%) for 11 measurements: PAC, NLH, OBB, EKB, MAL, FOB, NLB, OBH, ZOB, DKB, and MDH (2.01%–9.34%). The percentage differences were not systematically larger for measurements taken by the same user on both modalities than those obtained by different users on the same modality. When physical and MSCT measurements were tested on sex classification standards, the proportion of crania classified as male or female did not significantly differ (p > 0.05). The study showed that physical and virtual cranial measurements could be interchangeable for developing or applying sex estimation standards. However, clarifications and adaptations are necessary for measurements of mastoid, nasal, and orbital regions that did not meet the standard criteria.

forensic anthropology ; interobserver error ; intraobserver error ; MSCT ; osteometry ; virtual skeletal collection

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

67 (5)

2022.

1938-1947

objavljeno

0022-1198

1556-4029

10.1111/1556-4029.15100

Povezanost rada

Etnologija i antropologija, Kliničke medicinske znanosti, Temeljne medicinske znanosti

Poveznice
Indeksiranost