Modelling and experimental verification of device with a submerged evaporator for beer cooling (CROSBI ID 718209)
Prilog sa skupa u zborniku | izvorni znanstveni rad | međunarodna recenzija
Podaci o odgovornosti
Šare, Nina ; Vuletić Komljen, Branimir ; Matuško, Jadranko ; Osman, Krešimir
engleski
Modelling and experimental verification of device with a submerged evaporator for beer cooling
The paper presents a mathematical model of a submerged evaporator laboratory plant for cooling beer. The model is derived as a system with distributed parameters of the counterclockwise type. Additionally, the results of the experimental testing of the submerged evaporator laboratory plant are presented and based on such simplified a static model is identified, which is suitable for control system design.
verification, comparison, mathematical model, experiment, submerged evaporator, beer cooling
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
Podaci o prilogu
919-924.
2022.
objavljeno
10.23919/MIPRO55190.2022.9803657
Podaci o matičnoj publikaciji
MIPRO 2022 45th Jubilee International Convention Proceedings
Skala, Karolj
Rijeka: Hrvatska udruga za informacijsku i komunikacijsku tehnologiju, elektroniku i mikroelektroniku - MIPRO
1847-3938
1847-3946
Podaci o skupu
MIPRO 2022
predavanje
23.05.2022-27.05.2022
Opatija, Hrvatska