Would turbine uprating be allowable with respect to cavitation? : An example of vibroacoustic diagnosis (CROSBI ID 466050)

Prilog sa skupa u zborniku | izvorni znanstveni rad | međunarodna recenzija

Bajić, Branko Would turbine uprating be allowable with respect to cavitation? : An example of vibroacoustic diagnosis // Third International Symposium on Cavitation, Proceedings, Vol. 1 / Michel, J.M ; Kato, H. (ur.). 1998. str. 359-362-x

Podaci o odgovornosti

Bajić, Branko

engleski

Would turbine uprating be allowable with respect to cavitation? : An example of vibroacoustic diagnosis

Velocity field disturbances at the inflow to the runner of a turbine caused by the stay and guide vanes alter the vibroacoustic cavitation signature. The telltale amplitude modulation can be a means to identify the incipient, weak, or moderate cavitation related to each vane/runner blade pair. An application of this method is presented identifying the turbine parts responsible for the increase of cavitation predicted when uprating a 60 MW Kaplan turbine.

cavitation; erosion; turbine; uprating

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

359-362-x.

1998.

objavljeno

Podaci o matičnoj publikaciji

Third International Symposium on Cavitation, Proceedings, Vol. 1

Michel, J.M ; Kato, H.

Podaci o skupu

Third International Symposium on Cavitation

predavanje

07.04.1998-10.04.1998

Grenoble, Francuska

Povezanost rada

Strojarstvo