Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

The usefulness of wideband absorbance in the diagnosis of otosclerosis (CROSBI ID 308332)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Kelava, Iva ; Ries, Mihael ; Valent, Anđa ; Ajduk, Jakov ; Trotić, Robert ; Košec, Andro ; Bedeković, Vladimir The usefulness of wideband absorbance in the diagnosis of otosclerosis // International journal of audiology, 59 (2020), 11; 859-865. doi: 10.1080/14992027.2020.1785644

Podaci o odgovornosti

Kelava, Iva ; Ries, Mihael ; Valent, Anđa ; Ajduk, Jakov ; Trotić, Robert ; Košec, Andro ; Bedeković, Vladimir

engleski

The usefulness of wideband absorbance in the diagnosis of otosclerosis

Objective: To compare wideband absorbance (WBA) patterns between ears with otosclerosis and normal hearing ears and to investigate if WBA findings could be useful in the diagnosis of otosclerosis.Design: WBA was obtained at 107 frequency samples ranging from 0.226 to 8 kHz (24 per octave). A T-test was performed to compare between WBA in ears with otosclerosis and in normal hearing ears. The ability of WBA to discriminate between the patients with otosclerosis from the normal hearing participants was tested with a receiver operating characteristics (ROC) curve analysis.Study sample: Thirty-five patients with otosclerosis (age 31-64) and thirty-five normal hearing volunteers (age 32-64).Results: In frequency range 0.432-1.059 kHz, mean WBA in otosclerosis was significantly lower than mean WBA in normal hearing ears and in frequency range 4.238-8 kHz mean WBA in otosclerosis was significantly higher than mean WBA in normal hearing ears. The ROC analysis revealed that ears with otosclerosis and normal hearing ears could be distinguished based on mean WBA in frequency range >0.5 ≤ 1 kHz (AUC = 0.673) and based on mean WBA in frequency range >4 ≤ 8 kHz (AUC = 0.769).Conclusion: Our results suggest that WBA findings in ears with otosclerosis differ from WBA findings in normal hearing ears.

Otosclerosis ; energy absorbance ; wideband absorbance ; wideband reflectance

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

59 (11)

2020.

859-865

objavljeno

1499-2027

10.1080/14992027.2020.1785644

Povezanost rada

Biotehnologija u biomedicini (prirodno područje, biomedicina i zdravstvo, biotehničko područje), Kliničke medicinske znanosti, Kognitivna znanost (prirodne, tehničke, biomedicina i zdravstvo, društvene i humanističke znanosti)

Poveznice
Indeksiranost