Karakterizacija jetrenih tumora kontrastnim ultrazvukom: rezultati iz tercijarnog centra (CROSBI ID 307693)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Grgurević, Ivica ; Bokun, Tomislav ; Huzjan- Korunić, Renata ; Vukelić-Marković, Mirjana ; Brkljačić, Boris ; Ivanac, Gordana ; Aralica, Gorana ; Štoos-Veić, Tajana ; Lukić, Anita ; Banić, Marko et al. Karakterizacija jetrenih tumora kontrastnim ultrazvukom: rezultati iz tercijarnog centra // Liječnički vjesnik : glasilo Hrvatskoga liječničkog zbora, 5-6 (2018), 150-159

Podaci o odgovornosti

Grgurević, Ivica ; Bokun, Tomislav ; Huzjan- Korunić, Renata ; Vukelić-Marković, Mirjana ; Brkljačić, Boris ; Ivanac, Gordana ; Aralica, Gorana ; Štoos-Veić, Tajana ; Lukić, Anita ; Banić, Marko ; Kujundžić, Milan

hrvatski

Karakterizacija jetrenih tumora kontrastnim ultrazvukom: rezultati iz tercijarnog centra

Aim: To demonstrate the results of contrast-enhanced ultrasound (CEUS) for diagnostic characterization of liver tumors (LT) in a tertiary-care hospital. Patients and methods: Results of CEUS examinations of LT in successively included patients from January 1st 2015 to December 31st 2016 were retrospectively analyzed. Definite diagnosis was made through standardized clinical workup including MRI and/or MSCT, tissue sampling (biopsy or cytology) in cases when imaging was inconclusive, as well as pathohistological analysis of resected specimens in patients that underwent surgery. Results: In 90 patients (48 M, 42 F ; age 57±15) 132 LT were analyzed (68 benign and 64 malignant), with average size of 30 (8-130) mm. CEUS demonstrated excellent diagnostic performance to differentiate between benign and malignant LT (sensitivity 98.44%, specifi city 83.82%, AUC 0.91), without adverse reactions. Conclusion: Our results demonstrate high diagnostic accuracy and safety of CEUS for characterization of LT.

jetreni tumor ; ultrazvuk ; kontrastna sredstva ; osjetljivost ; specifičnost ; dijagnostika

nije evidentirano

engleski

Characterization of liver tumors by contrast- enhanced ultrasound: single centre experience

nije evidentirano

liver tumors ; constrast agents ; sensitivity ; specificity ; diagnosis

nije evidentirano

Podaci o izdanju

5-6

2018.

150-159

objavljeno

0024-3477

1849-2177

Povezanost rada

Kliničke medicinske znanosti