Heat Transfer Enhancement of Crossflow Air-to- Water Fin-and-Tube Heat Exchanger by Using Delta- Winglet Type Vortex Generators (CROSBI ID 307113)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Batista, Josip ; Trp, Anica ; Lenic, Kristian Heat Transfer Enhancement of Crossflow Air-to- Water Fin-and-Tube Heat Exchanger by Using Delta- Winglet Type Vortex Generators // Energies (Basel), 15 (2022), 6; 2070, 25. doi: 10.3390/en15062070

Podaci o odgovornosti

Batista, Josip ; Trp, Anica ; Lenic, Kristian

engleski

Heat Transfer Enhancement of Crossflow Air-to- Water Fin-and-Tube Heat Exchanger by Using Delta- Winglet Type Vortex Generators

The aim of this work is to numerically analyse fluid flow and heat transfer characteristics in a crossflow air-to-water fin-and-tube heat exchanger (FTHEX) by implementing two configurations of delta-winglet type vortex generators at the air side: delta-winglet upstream (DWU) and delta- winglet downstream (DWD). The vortex generators are mounted on a fin surface and deployed in a “common flow up” orientation. The effects of attack angles of 15°, 30° and 45° on air-side heat transfer and pressure drop were examined. Since the implementation of the full-size model would involve large numerical resources, the computational domain is simplified by considering a small segment in the direction of water flow. The fully developed temperature and velocity boundary conditions were set at the water inlets. To validate the defined mathematical model and numerical procedure, measurements have been performed on a plain FTHEX. The air side Reynolds number, based on hydraulic diameter, was in the range of 176 ≤ ReDh ≤ 400 and water side Reynolds number, based on inner tube diameter, was constant Redi = 17, 065. The results have shown that the highest increase in the Colburn factor j (by 11– 27%) and reduction in the air-side thermal resistance fraction (from 78.2–76.9% for ReDh = 176 to 76–72.4% for ReDh= 400) is achieved by using the DWD configuration with attack angle 45°. In addition, the overall heat transfer coefficient is improved by up to 15.7%. The DWD configuration with the attack angle 30° provides the greatest improvement in the heat transfer to pressure loss ratio, 5.2–15.4% over the range of ReDh studied.

crossflow air-to-water fin-and-tube heat exchanger ; conjugated heat transfer ; air side vortex generators ; numerical analysis

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

15 (6)

2022.

2070

25

objavljeno

1996-1073

10.3390/en15062070

Trošak objave rada u otvorenom pristupu

Povezanost rada

Strojarstvo, Temeljne tehničke znanosti

Poveznice