Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Inter-laboratory workflow for forensic applications: Classification of car glass fragments (CROSBI ID 306006)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Kaspi, Omer ; Israelsohn-Azulay, Osnat ; Yigal, Zidon ; Rosengarten, Hila ; Krmpotić, Matea ; Gouasmia, Sabrina ; Bogdanović Radović, Iva ; Jalkanen, Pasi ; Liski, Anna ; Mizohata, Kenichiro et al. Inter-laboratory workflow for forensic applications: Classification of car glass fragments // Forensic science international, 333 (2022), 111216, 9. doi: 10.1016/j.forsciint.2022.111216

Podaci o odgovornosti

Kaspi, Omer ; Israelsohn-Azulay, Osnat ; Yigal, Zidon ; Rosengarten, Hila ; Krmpotić, Matea ; Gouasmia, Sabrina ; Bogdanović Radović, Iva ; Jalkanen, Pasi ; Liski, Anna ; Mizohata, Kenichiro ; Räisänen, Jyrki ; Girshevitz, Olga ; Senderowitz, Hanoch

engleski

Inter-laboratory workflow for forensic applications: Classification of car glass fragments

The International Atomic Energy Agency (IAEA) has coordinated a research project titled ”Enhancing Nuclear Analytical Techniques to Meet the Needs of Forensics Sciences” (CRP F11021) with the aim of empowering accelerator and reactor based techniques for applications in forensic sciences. One of the key topics of this project was the analysis and classification of forensic glass specimens using Ion Beam Analysis (IBA) techniques and in particular, Particle Induced X-ray Emission (PIXE). To this end, glass fragments from car windows from different car models and manufacturers provided by the Israeli police force were subjected to PIXE measurements at three laboratories to determine their elemental compositions and possible glass corrosion. Major and trace elements were measured and given as an input to machine learning (ML) algorithms in order to develop classification models to determine the origin of the glass samples. First, we have developed ML models based on the results obtained at each lab. These models successfully classified glass fragments into different car models with an accuracy >80% on external test sets. Next, we demonstrated that following an appropriate pre-processing step, results from different labs could be combined into a single unified database for the derivation of a classification model. This model demonstrates good performances that matches or surpasses the performances of models derived from the individual labs. This finding paves the way towards establishing an international database that is composed of measurements from various PIXE labs. We believe that using this methodology of combining various sources of measurements will improve models’ performances and generality and will make the models accessible to law enforcement agencies around the world.

PIXE ; car window glass fragments ; Machine Learning ; Forensics

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

333

2022.

111216

9

objavljeno

0379-0738

1872-6283

10.1016/j.forsciint.2022.111216

Povezanost rada

Fizika, Kemija

Poveznice
Indeksiranost