Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

Evaluation of Serological Methods and a New Real-Time Nested PCR for Small Ruminant Lentiviruses (CROSBI ID 305102)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Schaer, Jessica ; Cvetnic, Zeljko ; Sukalic, Tomislav ; Dörig, Sven ; Grisiger, Martin ; Iscaro, Carmen ; Feliziani, Francesco ; Pfeifer, Folke ; Origgi, Francesco ; Zanoni, Reto Giacomo et al. Evaluation of Serological Methods and a New Real-Time Nested PCR for Small Ruminant Lentiviruses // Pathogens, 11 (2022), 2; 129, 21. doi: 10.3390/pathogens11020129

Podaci o odgovornosti

Schaer, Jessica ; Cvetnic, Zeljko ; Sukalic, Tomislav ; Dörig, Sven ; Grisiger, Martin ; Iscaro, Carmen ; Feliziani, Francesco ; Pfeifer, Folke ; Origgi, Francesco ; Zanoni, Reto Giacomo ; Abril, Carlos Eduardo

engleski

Evaluation of Serological Methods and a New Real-Time Nested PCR for Small Ruminant Lentiviruses

Small ruminant lentiviruses (SRLVs), i.e., CAEV and MVV, cause insidious infections with life-long persistence and a slowly progressive disease, impairing both animal welfare and productivity in affected herds. The complex diagnosis of SRLVs currently combines serological methods including whole-virus and peptide-based ELISAs and Immunoblot. To improve the current diagnostic protocol, we analyzed 290 sera of animals originating from different European countries in parallel with three commercial screening ELISAs, Immunoblot as a confirmatory assay and five SU5 peptide ELISAs for genotype differentiation. A newly developed nested real-time PCR was carried out for the detection and genotype differentiation of the virus. Using a heat-map display of the combined results, the drawbacks of the current techniques were graphically visualized and quantified. The immunoblot and the SU5-ELISAs exhibited either unsatisfactory sensitivity or insufficient reliability in the differentiation of the causative viral genotype, respectively. The new truth standard was the concordance of the results of two out of three screening ELISAs and the PCR results for serologically false negative samples along with genotype differentiation. Wholevirus antigen-based ELISA showed the highest sensitivity (92.2%) and specificity (98.9%) among the screening tests, whereas PCR exhibited a sensitivity of 75%.

small ruminant lentivirus ; Maedi-Visna ; caprine arthritis-encephalitis ; diagnosis ; serological methods ; molecular methods ; ELISA ; nested real-time PCR

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

11 (2)

2022.

129

21

objavljeno

2076-0817

10.3390/pathogens11020129

Povezanost rada

Veterinarska medicina

Poveznice
Indeksiranost