Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

Results of Multicenter Evaluation of Plug Use for LVAD Explantation (CROSBI ID 713501)

Prilog sa skupa u časopisu | sažetak izlaganja sa skupa | međunarodna recenzija

Potapov, E. ; Politis, N. ; Rieger, S. ; Karck, M. ; Weyand, M. ; Walther, T. ; Emrich, F. ; Reichenspurrner, H. ; Bernhadt, A. ; Barten, M.J. et al. Results of Multicenter Evaluation of Plug Use for LVAD Explantation // Journal of heart and lung transplantation. 2021. doi: 10.1016/j.healun.2021.01.1176

Podaci o odgovornosti

Potapov, E. ; Politis, N. ; Rieger, S. ; Karck, M. ; Weyand, M. ; Walther, T. ; Emrich, F. ; Reichenspurrner, H. ; Bernhadt, A. ; Barten, M.J. ; Svenarud, P. ; Gummert, J. ; Simon, A. ; Sef, Davorin ; Doenst, T. ; Tsyganenko, D. ; Falk, V.

engleski

Results of Multicenter Evaluation of Plug Use for LVAD Explantation

Purpose Use of a special designed plug is one of the recommended methods for LVAD explantation in case of myocardial recovery (IIa in EACTS expert opinion). The study presents the results from the evaluation of the long-term follow up in patients that received a titanium sintered plug after LVAD explantation. Methods In this retrospective, multi-center analysis 67 patients were enrolled who received a titanium sintered plug after LVAD explantation. Information were collected through a questionnaire containing questions about demographics, surgical procedure and the follow- up. Results Date of last follow-up was successfully recorded for 67 patients and was measured in months. The mean follow-up was 29±27 months ; 64% of patients presented > 1 year follow up. At the time of the last follow-up 82% of patients were alive, one patient developed plug infection due to infected part of incorporated driveline. Conclusion In this multicenter study, the use of an individually manufactured titanium plug to close the opening of the apex after LVAD explantation resulted in low incidence of plug- related complications. With the volume of patient undergoing an LVAD explantation after myocardial recovery increasing, the need of industry manufactured plugs is evident.

LVAD Explantation

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

S420

2021.

nije evidentirano

objavljeno

10.1016/j.healun.2021.01.1176

Podaci o matičnoj publikaciji

Journal of heart and lung transplantation

Elsevier

1053-2498

1557-3117

Podaci o skupu

ISHLT2021 41st Annual Meeting & Scientific Sessions

predavanje

24.04.2021-28.04.2021

online

Povezanost rada

Kliničke medicinske znanosti

Poveznice
Indeksiranost