Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

Minimally invasive aortic valve replacement with sutureless bioprosthesis through right minithoracotomy with completely central cannulation—Early results in 203 patients (CROSBI ID 304101)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Sef, Davorin ; Krajnc, Martina ; Klokocovnik, Tomislav Minimally invasive aortic valve replacement with sutureless bioprosthesis through right minithoracotomy with completely central cannulation—Early results in 203 patients // Journal of cardiac surgery, 36 (2020), 2; 558-564. doi: 10.1111/jocs.15257

Podaci o odgovornosti

Sef, Davorin ; Krajnc, Martina ; Klokocovnik, Tomislav

engleski

Minimally invasive aortic valve replacement with sutureless bioprosthesis through right minithoracotomy with completely central cannulation—Early results in 203 patients

Objectives: Minimally invasive aortic valve replacement (mini-AVR) might improve clinical outcomes, particularly in high-risk and elderly patients. Sutureless/rapid deployment bioprosthesis can offer advantage of decreasing the cross-clamp time (XCT) and easing the procedure. Our aim was to evaluate the safety and perioperative outcomes of mini-AVR using sutureless bioprothesis via the right minithoracotomy approach with our modified technique of central cannulation. Methods: We performed a single-center retrospective analysis of 203 patients consecutively undergoing isolated AVR between March 2016 and June 2018 with the right minithoracotomy approach and our modified technique of central cannulation. Aortic valve diseases were stenosis (89.9%), regurgitation (1.6%), and mixed valve disease (8.5%). Patients with concomitant procedures were excluded. Primary endpoints were 30-day and 4-month mortality. Results: Mean age was 76 ± 6.2 years, 63 (31%) patients were 80 years or older. Cardiopulmonary bypass and XCT were 60.5 (39-153) and 35 (24-76) min, respectively. Thirty-day and 4-month mortality were 1% (two patients). We have observed minor paravalvular leak (PVL) which occurred in seven patients (3.4%), and no moderate/severe PVL was found perioperatively. One patient developed moderate/severe PVL during the 4-month follow-up. There was no structural valve degeneration. Two (1%) patients needed conversion to full sternotomy, and two (1%) patients to ministernotomy. Conclusions: Mini-AVR via the right minithoracotomy approach with central cannulation is an effective and safe procedure and demonstrates excellent early clinical outcomes. This approach can be particularly valuable in higher risk and elderly patients.

Perceval valve ; aortic valve replacement ; minimally invasive cardiac surgery ; right minithoracotomy ; sutureless/rapid deployment valve

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

36 (2)

2020.

558-564

objavljeno

0886-0440

1540-8191

10.1111/jocs.15257

Povezanost rada

Povezane osobe



Kliničke medicinske znanosti

Poveznice
Indeksiranost