Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Effect of Conventional Adhesive Application or Co- Curing Technique on Dentin Bond Strength (CROSBI ID 303535)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Vukelja, Josipa ; Klarić Sever, Eva ; Sever, Ivan ; Jukić Krmek, Silvana ; Tarle, Zrinka Effect of Conventional Adhesive Application or Co- Curing Technique on Dentin Bond Strength // Materials, 14 (2021), 24; 7664, 13. doi: 10.3390/ma14247664

Podaci o odgovornosti

Vukelja, Josipa ; Klarić Sever, Eva ; Sever, Ivan ; Jukić Krmek, Silvana ; Tarle, Zrinka

engleski

Effect of Conventional Adhesive Application or Co- Curing Technique on Dentin Bond Strength

The aim of this in vitro study was to assess the effect of two different adhesive application methods on shear dentin bond strength (ISO 29022) using three various adhesive systems. A midcoronal section of 77 intact third human molars with fully developed apices was made to create flat bonding substrates. The materials used in the study were Excite F (Ivoclar Vivadent), Prime&Bond Universal (Dentsply Sirona) and G-Premio Bond (GC). The application of each adhesion system was performed in two different ways. In the first group, the bonding agent was light cured immediately after the application (conventional method), while in the second group the adhesive and composite were cured concurrently (“co-curing” method). A total of 180 specimens were prepared (3 adhesives × 2 method of application × 30 specimens per experimental group), stored at 37 ◦C in distilled water and fractured in shear mode after 1 week. Statistical analysis was performed using ANOVA and Weibull statistics. The highest bond strength was obtained for Prime&Bond conventional (21.7 MPa), whilst the lowest bond strength was observed when co-curing was used (particularly, Excite F 12.2 MPa). The results showed a significant difference between conventional and co-curing methods in all materials. According to reliability analysis, the co-curing method diminished bond reliability. Different application techniques exhibit different bond strengths to dentin

dentin bond strength ; shear bond strength ; co-curing ; reliability analysis

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

14 (24)

2021.

7664

13

objavljeno

1996-1944

10.3390/ma14247664

Trošak objave rada u otvorenom pristupu

Povezanost rada

Dentalna medicina

Poveznice
Indeksiranost