An analysis of voltage source inverter switches fault classification using short time Fourier transformation (CROSBI ID 303080)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Mustafa, Manap ; Nikolovski, Srete ; Aleksandr, Skamyin ; Rony, Karim4 ; Tole, Sutikno ; Mohd, Hatta, Jopri ; An analysis of voltage source inverter switches fault classification using short time Fourier transformation // International journal of power electronics and drive systems, 12 (2021), 4; 2209-2220. doi: 10.11591/ijpeds.v12.i4.pp2209-2220

Podaci o odgovornosti

Mustafa, Manap ; Nikolovski, Srete ; Aleksandr, Skamyin ; Rony, Karim4 ; Tole, Sutikno ; Mohd, Hatta, Jopri ;

engleski

An analysis of voltage source inverter switches fault classification using short time Fourier transformation

The dependability of power electronics systems, such as three-phase inverters, is critical in a variety of applications. Different types of failures that occur in an inverter circuit might affect system operation and raise the entire cost of the manufacturing process. As a result, detecting and identifying inverter problems for such devices is critical in industry. This study presents the short-time Fourier transform (STFT) for fault classification and identification in three-phase type, voltage source inverter (VSI) switches. Time-frequency representation (TFR) represents the signal analysis of STFT, which includes total harmonic distortion, instantaneous RMS current, RMS fundamental current, total non harmonic distortion, total waveform distortion and average current. The features of the faults are used with a rule-based classifier based on the signal parameters to categorise and detect the switch faults. The suggested method's performance is evaluated using 60 signals containing short and open circuit faults with varying characteristics for each switch in VSI. The classification results demonstrate the proposed technique is good to be implemented for VSI switches faults classification, with an accuracy classification rate of 98.3%

Open circuit fault, Rule-based classifier, Short circuit fault, Short time Fourier transform, Voltage source inverter

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

12 (4)

2021.

2209-2220

objavljeno

2088-8694

2722-256X

10.11591/ijpeds.v12.i4.pp2209-2220

Trošak objave rada u otvorenom pristupu

Povezanost rada

Elektrotehnika

Poveznice