X-Ray measurements of radiation hard monolithic CMOS sensors at Diamond Light Source (CROSBI ID 711183)
Prilog sa skupa u zborniku | izvorni znanstveni rad
Podaci o odgovornosti
Mironova, Maria ; Metodiev, Kaloyan ; Allport, Philip Patrick ; Berdalović, Ivan ; Bortoletto, Daniela ; Buttar, Craig ; Cardella, Roberto ; Dao, Valerio ; Dyndal, Mateusz ; Freeman, Patrick Moriishi ; Flores Sanz de Acedo, Leyre ; Gonella, Laura ; Kugathasan, Thanushan ; Pernegger, Heinz ; Piro, Francesco ; Plackett, Richard ; Riedler, Petra ; Sharma, Abhishek ; Schioppa, Enrico Junior ; Shipsey, Ian ; Solans Sanchez, Carlos ; Snoeys, Walter ; Wennlöf, Hakan ; Weatherill, Daniel ; Wood, Daniel ; Worm, Steven
engleski
X-Ray measurements of radiation hard monolithic CMOS sensors at Diamond Light Source
This contribution outlines the results of investigations into the effects of radiation damage in the mini-MALTA depleted monolithic pixel sensor prototype using a micro-focus X-ray beam at Diamond Light Source. The in-pixel photon response was measured for three different pixel design variations: one with the standard continuous n- layer layout and standard front-end, and extra deep p-well and n- gap designs with a modified front-end. The standard design showed a decrease of 12% in pixel response after irradiation to 1e15 neq/cm2. The two new designs did not show a significant decrease in pixel response after irradiation.
Electronic detector readout concepts (solid-state) ; Front-end electronics for detector readout ; Particle tracking detectors ; Radiation-hard detectors
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
Podaci o prilogu
-
2020.
objavljeno
10.22323/1.373.0054
Podaci o matičnoj publikaciji
Proceedings of Science, The 28th International Workshop on Vertex Detectors (Vertex2019)
Sissa Medialab
Podaci o skupu
Nepoznat skup
poster
29.02.1904-29.02.2096