Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Diagnostic accuracy of modified Hadlock formula for fetal macrosomia in women with gestational diabetes and pregnancy weight gain above recommended (CROSBI ID 301386)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Lovrić, Boris ; Šijanović, Siniša ; Lešin, Joško ; Juras, Josip Diagnostic accuracy of modified Hadlock formula for fetal macrosomia in women with gestational diabetes and pregnancy weight gain above recommended // Journal of perinatal medicine, 49 (2021), 7; 907-914. doi: 10.1515/jpm-2021-0013

Podaci o odgovornosti

Lovrić, Boris ; Šijanović, Siniša ; Lešin, Joško ; Juras, Josip

engleski

Diagnostic accuracy of modified Hadlock formula for fetal macrosomia in women with gestational diabetes and pregnancy weight gain above recommended

Objectives: Women with gestational diabetes (GDM) and weight gain during pregnancy above recommended more -often give birth to macrosomic children. The goal of this study was to evaluate the diagnostic accuracy of the modified formula for ultrasound assessment of fetal weight created in a pilot study using a similar specimen in comparison to the Hadlock-2 formula. Methods: This is a prospective, cohort, applicative, observational, quantitative, and analytical study, which included 213 pregnant women with a singleton pregnancy, GDM, and pregnancy weight gain above recommended. Participants were consecutively followed in the time period between July 1st, 2016, and August 31st, 2020. Ultrasound estimations were made within three days before the delivery. Fetal weights estimated using both formulas were compared to the newborns’ weights. Results: A total of 133 fetal weight estimations were made. In comparison to the newborns’ weight modified formula had significantly smaller deviation in weight estimation compared to the Hadlock-2 formula, higher frequency of deviation within 5% of newborns weights (78.2% [95% CI=0.74–0.83] vs. 60.2%), smaller frequency of deviations from 5 to 10% (19.5 vs. 33.8%) and above 10%, which was even more significant among macrosomic children. There were 36/50 (72%) correctly diagnosed cases of macrosomia by modified and 33/50 (66%) by Hadlock- 2 formula. Area under the curve (AUC) for the modified formula was 0.854 (95% CI=0.776–0.932), and for the Hadlock-2 formula 0.824 (95% CI=0.740– 0.908). The positive predictive value of the modified formula was 81.81%, the negative 97.91%. Conclusions: In cases of greater fetal weights, the modified formula showed greater precision.

accuracy ; comparison ; fetal weight ; Hadlock-2 formula ; macrosomia ; modified formula ; ultrasound assessment

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

49 (7)

2021.

907-914

objavljeno

0300-5577

1619-3997

10.1515/jpm-2021-0013

Povezanost rada

Biotehnologija u biomedicini (prirodno područje, biomedicina i zdravstvo, biotehničko područje), Kliničke medicinske znanosti

Poveznice
Indeksiranost