Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Elastic modulus and elasticity ratio of malignant breast lesions with shear wave ultrasound elastography: variations with different region of interest and lesion size (CROSBI ID 300451)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Bulum, Antonio ; Ivanac, Gordana ; Divjak, Eugen ; Biondić Špoljar, Iva ; Džoić Dominković, Martina ; Bojanić, Kristina ; Lucijanić, Marko ; Brkljačić, Boris Elastic modulus and elasticity ratio of malignant breast lesions with shear wave ultrasound elastography: variations with different region of interest and lesion size // Diagnostics, 11 (2021), 6; 1015, 8. doi: 10.3390/diagnostics11061015

Podaci o odgovornosti

Bulum, Antonio ; Ivanac, Gordana ; Divjak, Eugen ; Biondić Špoljar, Iva ; Džoić Dominković, Martina ; Bojanić, Kristina ; Lucijanić, Marko ; Brkljačić, Boris

engleski

Elastic modulus and elasticity ratio of malignant breast lesions with shear wave ultrasound elastography: variations with different region of interest and lesion size

Shear wave elastography (SWE) is a type of ultrasound elastography with which the elastic properties of breast tissues can be quantitatively assessed. The purpose of this study was to determine the impact of different regions of interest (ROI) and lesion size on the performance of SWE in differentiating malignant breast lesions. The study included 150 female patients with histopathologically confirmed malignant breast lesions. Minimal (Emin), mean (Emean), maximal (Emax) elastic modulus and elasticity ratio (e-ratio) values were measured using a circular ROI size of 2, 4 and 6 mm diameters and the lesions were divided into large (diameter ≥ 15 mm) and small (diameter < 15 mm). Highest Emin, Emean and e-ratio values and lowest variability were observed when using the 2 mm ROI. Emax values did not differ between different ROI sizes. Larger lesions had significantly higher Emean and Emax values, but there was no difference in e-ratio values between lesions of different sizes. In conclusion, when measuring the Emin, Emean and e- ratio of malignant breast lesions using SWE the smallest possible ROI size should be used regardless of lesion size. ROI size has no impact on Emax values while lesion size has no impact on e-ratio values.

breast ; ultrasound ; elastography ; cancer ; imaging