Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

Experimental Characterization of Optimized Piezoelectric Energy Harvesters for Wearable Sensor Networks (CROSBI ID 299909)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Gljušćić, Petar ; Zelenika, Saša Experimental Characterization of Optimized Piezoelectric Energy Harvesters for Wearable Sensor Networks // Sensors, 21 (2021), 21; 7042, 25. doi: 10.3390/s21217042

Podaci o odgovornosti

Gljušćić, Petar ; Zelenika, Saša

engleski

Experimental Characterization of Optimized Piezoelectric Energy Harvesters for Wearable Sensor Networks

The development of wearable devices and remote sensor networks progressively relies on their increased power autonomy, which can be further expanded by replacing conventional power sources, characterized by limited lifetimes, with energy harvesting systems. Due to its pervasiveness, kinetic energy is considered as one of the most promising energy forms, especially when combined with the simple and scalable piezoelectric approach. The integration of piezoelectric energy harvesters, generally in the form of bimorph cantilevers, with wearable and remote sensors, highlighted a drawback of such a configuration, i.e., their narrow operating bandwidth. In order to overcome this disadvantage while maximizing power outputs, optimized cantilever geometries, developed using the design of experiments approach, are analysed and combined in this work with frequency up-conversion excitation that allows converting random kinetic ambient motion into a periodical excitation of the harvester. The developed optimised designs, all with the same harvesters’ footprint area of 23 × 15 mm, are thoroughly analysed via coupled harmonic and transient numerical analyses, along with the mostly neglected strength analyses. The models are validated experimentally via innovative experimental setups. The thus-proposed f = 50 mm watch-like prototype allows, by using a rotating flywheel, the collection of low-frequency (ca. 1 to 3 Hz) human kinetic energy, and the periodic excitation of the optimized harvesters that, oscillating at their eigenfrequencies (~325 to ~930 Hz), display specific power outputs improved by up to 5.5 times, when compared to a conventional rectangular form, with maximal power outputs of up to >130 mW and average power outputs of up to >3 mW. These power levels should amply satisfy the requirements of factual wearable medical systems, while providing also an adaptability to accommodate several diverse sensors. All of this creates the preconditions for the development of novel autonomous wearable devices aimed not only at sensor networks for remote patient monitoring and telemedicine, but, potentially, also for IoT and structural health monitoring.

piezoelectric energy harvesters ; medical sensor networks ; DoE ; frequency up-conversion ; optimized geometry ; FE numerical modelling ; experimental assessment

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

21 (21)

2021.

7042

25

objavljeno

1424-8220

10.3390/s21217042

Trošak objave rada u otvorenom pristupu

Povezanost rada

Interdisciplinarne tehničke znanosti, Strojarstvo, Temeljne tehničke znanosti

Poveznice
Indeksiranost