Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

Koncept termometara s dva osjetnika temperature za kontinuirano praćenje drifta termoparova (CROSBI ID 709175)

Prilog sa skupa u zborniku | sažetak izlaganja sa skupa

Šestan, Danijel ; Zvizdić, Davor ; Matas, Ivan ; Arifovic, Narcisa ; Thurzo-Andras, E. ; Spasova, S. ; Nedialkov, S. ; Aldev, K. ; Neagu, D. ; Strnad, R. et al. Koncept termometara s dva osjetnika temperature za kontinuirano praćenje drifta termoparova // Knjiga sažetaka (Book of abstracts) 16. međunarodne konferencije "Kompetentnost laboratorija" CROLAB 2021 / Grgec Bermanec, Lovorka (ur.). CROLAB - Hrvatski laboratoriji, 2021. str. 107-108

Podaci o odgovornosti

Šestan, Danijel ; Zvizdić, Davor ; Matas, Ivan ; Arifovic, Narcisa ; Thurzo-Andras, E. ; Spasova, S. ; Nedialkov, S. ; Aldev, K. ; Neagu, D. ; Strnad, R. ; Šindelářová, L. ; Cohodarevic, S. ; Mutapčić, N. ; Lulić, H. ; Opel, K. ; Olsen, Å. A. F. ; Buzuc, G. ; Bordianu, C. ; Vukicevic, T.

hrvatski

Koncept termometara s dva osjetnika temperature za kontinuirano praćenje drifta termoparova

Within the work package one of the ongoing EMPIR project „Developing Traceable Measurement Capabilities for Monitoring Thermocouple Performance” (MetForTC), the novel concept of dual-type temperature probes was developed. By using dual-type temperature probes, users would be able to continuously monitor the thermocouple drift in-situ, including environments with varying temperatures. The concept is developed mainly for use in industry, where the drift of thermocouples can lead to various problems, such as increased energy consumption, loss of raw material, or decrease in quality of products. To mitigate the problems related to thermocouple drift, industrial users tend to replace thermocouples regularly, in some cases even after only a few days of usage. Using this approach, thermocouples can be occasionally replaced too early as well as too late. Dual-type temperature probe consists of a monitored thermocouple sensor and an additional temperature sensor, accommodated within the same protective sheath. The use of an additional (reference) sensor, which experiences a lower drift than the monitored thermocouple (e.g. higher grade thermocouple wires, platinum resistance sensors, or fiber-optic sensors), enables monitoring of thermocouple drift by continuous comparison of the differences in their temperature readings. While the drift of the monitored thermocouple can be tracked continuously, the concept also enables occasional tracking of drift of the reference sensor.

temperatura, termoparovi, drift, termometri s dva osjetnika temperature

nije evidentirano

engleski

Concept of dual-type temperature probes for in-situ monitoring of thermocouple drift

nije evidentirano

temperature measurement, thermocouple drift, dual-type thermometers

nije evidentirano

Podaci o prilogu

107-108.

2021.

objavljeno

Podaci o matičnoj publikaciji

Knjiga sažetaka (Book of abstracts) 16. međunarodne konferencije "Kompetentnost laboratorija" CROLAB 2021

Grgec Bermanec, Lovorka

CROLAB - Hrvatski laboratoriji

978-953-7329-24-2

Podaci o skupu

16. međunarodna konferencija: Kompetentnost laboratorija (CROLAB 2021)

poster

13.10.2021-16.10.2021

Brijuni, Hrvatska

Povezanost rada

Strojarstvo