Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

Preparation of wine for the analysis by analytical techniques: NMR, IRMS and ICP-OES– method validation (CROSBI ID 708353)

Prilog sa skupa u zborniku | izvorni znanstveni rad | međunarodna recenzija

Miloš, Mara ; Petric, Ivana Vladimira ; Jusup, Josipa ; Šimon, Silvio ; Leder, Renata ; Banović, Mara Preparation of wine for the analysis by analytical techniques: NMR, IRMS and ICP-OES– method validation // PROCEEDINGS of 9th International CONGRESS of Food Technologists, Biotechnologists and Nutritionists. 2018. str. 103-107

Podaci o odgovornosti

Miloš, Mara ; Petric, Ivana Vladimira ; Jusup, Josipa ; Šimon, Silvio ; Leder, Renata ; Banović, Mara

engleski

Preparation of wine for the analysis by analytical techniques: NMR, IRMS and ICP-OES– method validation

Stable isotopes and mineral composition of wines have been recognized as indicators of wine's authenticity, and methods for their determination have been developed. Stable isotope ratios of (D/H)I and (D/H)II of wine is determined by the SNIF-NMR® (Site Specific Natural Isotope Fractionation - Nuclear Magnetic Resonance) for the methyl- and the methylene-position of the ethanol molecule. The determination of 13C/12C is performed in the ethanol molecule by the IRMS - Isotope Ratio Mass Spectrometry. For both methods, ethanol from the wine is obtained using ADCS - Automated Distillation Control System. The residue after distillation is ethanol free and therefore suitable for determining the macro- and microelements by the ICP-OES (Inductively Coupled Plasma – Optical Emission Spectrometry) method. The aim of this paper was to validate the wine sample preparation by ADCS in order to obtain a distillate with an alcohol grade of 92-93% w/w. Repeatability of the method was determined by distillation of the same sample on four distillation columns in six replicates. Obtained mean value was 92.60 ± 0.23% w/w. The relative standard deviations (RSD) were calculated for each column and they were: 0.15, 0.13, 0.31, and 0.12%, respectively. Determination of the distillate water content was performed by KarlFischer titration method and the repeatability of water determination was calculated (RSD = 0.25%). It was concluded that the method is fit for the intended purpose, which is preparation of the wine sample for analysis by analytical techniques: NMR, IRMS and ICP-OES.

authenticity ; validation method of distillation ; wine

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

103-107.

2018.

objavljeno

Podaci o matičnoj publikaciji

PROCEEDINGS of 9th International CONGRESS of Food Technologists, Biotechnologists and Nutritionists

Podaci o skupu

9th International Congress of Food Technologists, Biotechnologists and Nutritionist

poster

03.10.2018-06.10.2018

Zagreb, Hrvatska

Povezanost rada

Biotehnologija, Kemija, Prehrambena tehnologija

Poveznice