Verification of technical characteristics and performance of VeinViewer Flex, ICEN IN-G090-2 and AccuVein AV400 transillumination devices (CROSBI ID 299189)

Prilog u časopisu | ostalo | međunarodna recenzija

Dorotić, Adrijana ; Kuktić, Ivana ; Vuljanić, Dora ; Šimundić, Ana-Maria Verification of technical characteristics and performance of VeinViewer Flex, ICEN IN-G090-2 and AccuVein AV400 transillumination devices // Clinica chimica acta, 519 (2021), 40-47. doi: 10.1016/j.cca.2021.04.001

Podaci o odgovornosti

Dorotić, Adrijana ; Kuktić, Ivana ; Vuljanić, Dora ; Šimundić, Ana-Maria

engleski

Verification of technical characteristics and performance of VeinViewer Flex, ICEN IN-G090-2 and AccuVein AV400 transillumination devices

Background and aim Transilluminator device allow healthcare professionals to visualize peripheral veins without using tourniquet. Aim of the study was to test the ability of three devices (Christie VeinViewer Flex (Christie, Lake Mary, Florida, USA), ICEN IN-G090-2 (ICEN Technology Company Limited, Guangdong, China) and AccuVein AV400 (AccuVein, New York, USA)) to present quality images thought defined criterion. Materials and methods Study was designed as a comparison of technical characteristics, evaluation of image quality and assessment of applicability in different conditions (different viewing angels, conditions of lightning and image visibility under interference of humidity and body lotions) in reference person on two venipuncture sites. Results Devices have different technical characteristics and vary in optimal distance for good quality image (18–30 cm), number of presented veins (1–4), image dimension (6.0–90.3 cm2), length (1.5–8.0 cm) and thickness (2–5 mm) of the dominant blood vessel. Devices present different image visibility under different viewing angels, conditions of lightning and interference of humidity and body lotions (from good quality to unusable images). Conclusion Transillumination devices differ in their technical characteristics and performance. The choice of the device should be based on the needs of the particular patient population and the intended use of the device.

Transillumination ; Phlebotomy ; Preanalytical phase

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

519

2021.

40-47

objavljeno

0009-8981

1873-3492

10.1016/j.cca.2021.04.001