Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Analysis of Seismic Action on the Tie Rod System in Historic Buildings Using Finite Element Model Updating (CROSBI ID 298999)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Ereiz, Suzana ; Duvnjak Ivan ; Damjanović, Domagoj ; Bartolac, Marko Analysis of Seismic Action on the Tie Rod System in Historic Buildings Using Finite Element Model Updating // Buildings, 11(10) (2021), 103390, 18

Podaci o odgovornosti

Ereiz, Suzana ; Duvnjak Ivan ; Damjanović, Domagoj ; Bartolac, Marko

engleski

Analysis of Seismic Action on the Tie Rod System in Historic Buildings Using Finite Element Model Updating

Historic buildings have a high architectural value and their maintenance, repair and rehabilitation require a special approach. This approach is mainly based on the buildings’ performance under non-destructive tests such as operational modal analysis (OMA). Under extreme loads, such as earthquakes, these buildings require representative numerical models to simulate their expected response. In historic buildings, tie rods transfer axial loads and are typically used to balance horizontal trust due to static and dynamic loads associated with seismic actions. It is very important to determine the possibility of exceeding their load-bearing capacity under extreme loads, such as an earthquake. In this context, this paper presents an approach for the analysis of seismic action on the tie rod system in a historic building. The analysis was performed by combining the on-site experimental testing and the finite element model updating (FEMU) of the local models of tie rods and the global model of the structure. It was shown that the combination of analyzing local and global structural models, experimental on-site testing and FEMU is a viable solution for assessment of historic buildings’ load bearing capacity.

seismic actions ; tie rod system ; finite element model updating (FEMU) ; structural health monitoring (SHM) ; mode shapes ; natural frequency

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

11(10)

2021.

103390

18

objavljeno

2075-5309

Povezanost rada

Građevinarstvo

Poveznice
Indeksiranost