Non-Destructive Examination of Membrane Walls Welding During Water Tube Boiler Manufacturing (CROSBI ID 707334)

Prilog sa skupa u zborniku | izvorni znanstveni rad | međunarodna recenzija

Herceg, Arijan ; Marić, Dejan ; Šolić, Tomislav ; Samardžić, Mijat ; Bašić, Aleksandar ; Samardžić, Ivan Non-Destructive Examination of Membrane Walls Welding During Water Tube Boiler Manufacturing // Zbornik radova 19. skup o prirodnom plinu, toplini i vodi, 19th Natural Gas, Heat and Water Conference, 12. međunarodni skup o prirodnom plinu, toplini i vodi, 12th International Natural Gas, Heat and Water Conference / Raos, Pero ; Galeta, Tomislav ; Kozak, Dražan et al. (ur.). Slavonski Brod: Sveučilište u Slavonskom Brodu, 2021. str. 173-182

Podaci o odgovornosti

Herceg, Arijan ; Marić, Dejan ; Šolić, Tomislav ; Samardžić, Mijat ; Bašić, Aleksandar ; Samardžić, Ivan

engleski

Non-Destructive Examination of Membrane Walls Welding During Water Tube Boiler Manufacturing

Membrane walls represent most used way to ensure efficient heat transfer between flue gasses and medium present in the tubes. Standards elements of the membrane wall are steel tubes and bars joined together by welding. This requires implementation of appropriate quality control system, which can reduce to minimum chances that welds with deficiencies leave manufacturing hall. In accordance with standards for both design and testing, following NDT methods have been chosen: visual testing (VT) for both dimensional and overall supervision of welding process, penetrant testing (PT) for detection of indications open to the examined surface and radiographic testing (RT) for detection of volumetric deficiencies. Technical characteristics of implemented NDT methods are shown in the experimental part of the paper. Results have shown that only by combination of both surface and volumetric NDT methods can achieve reliable results. While stating reliable results, it must not be assumed that this means total lack of deficiencies in general. Experimental part was conducted during manufacturing process of membrane walls in ĐĐ TEP d.o.o.

water tube boilers, membrane walls, visual testing (VT), penetrant testing (PT), radiographic testing (RT)

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

173-182.

2021.

objavljeno

Podaci o matičnoj publikaciji

Zbornik radova 19. skup o prirodnom plinu, toplini i vodi, 19th Natural Gas, Heat and Water Conference, 12. međunarodni skup o prirodnom plinu, toplini i vodi, 12th International Natural Gas, Heat and Water Conference

Raos, Pero ; Galeta, Tomislav ; Kozak, Dražan ; Raos, Marija ; Stojšić, Josip ; Sutlović, Igor ; Tonković, Zlatko

Slavonski Brod: Sveučilište u Slavonskom Brodu

1849-0638

Podaci o skupu

19. skup o prirodnom plinu, toplini i vodi = 19th Natural Gas, Heat and Water Conference ; 12. međunarodni skup o prirodnom plinu, toplini i vodi = 12th International Natural Gas, Heat and Water Conference

poster

22.09.2021-25.09.2021

Osijek, Hrvatska

Povezanost rada

Strojarstvo