Methodology and Measurement Setup for Determining PWM Contribution to Iron Loss in Laminated Ferromagnetic Materials (CROSBI ID 297808)
Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija
Podaci o odgovornosti
Sirotić, Igor ; Kovačić, Marinko ; Stipetić, Stjepan
engleski
Methodology and Measurement Setup for Determining PWM Contribution to Iron Loss in Laminated Ferromagnetic Materials
This article presents a novel methodology and experimental setup for measuring iron loss under pulsewidth-modulated (PWM) power supply using a ring sample of the ferromagnetic laminated core. A power converter based on silicon carbide technology was used to achieve high switching frequencies and near ideal output voltage. The unique feature of the proposed setup is iron loss measurement under dc magnetization bias using a single excitation winding supplied by the single- phase inverter. The research objective is to determine the influence of PWM and inverter parameters on iron losses and to establish the methodology for measurement and data processing required to produce loss data maps that can be used to improve the accuracy of the total loss estimate for an electrical machine.
DC bias , inverter , iron loss , laminated ferromagnetic materials , pulsewidth modulation (PWM) , ring core , silicon carbide (SiC)
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
Podaci o izdanju
57 (5)
2021.
4796-4804
objavljeno
0093-9994
1939-9367
10.1109/TIA.2021.3094501