Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Experimental Testing and Finite Element Method Analysis of the Anterior Cruciate Ligament Primary Repair with Internal Brace Augmentation (CROSBI ID 297469)

Prilog u časopisu | ostalo | međunarodna recenzija

Bonačić Bartolin, Petra ; Boixadera, Rachel ; Hudetz, Damir Experimental Testing and Finite Element Method Analysis of the Anterior Cruciate Ligament Primary Repair with Internal Brace Augmentation // Medical engineering & physics, 95 (2021), 76-83. doi: 10.1016/j.medengphy.2021.07.013

Podaci o odgovornosti

Bonačić Bartolin, Petra ; Boixadera, Rachel ; Hudetz, Damir

engleski

Experimental Testing and Finite Element Method Analysis of the Anterior Cruciate Ligament Primary Repair with Internal Brace Augmentation

The internal brace (IB) technique is a promising treatment option for repairing the proximal rupture of the anterior cruciate ligament (ACL). This paper presents a biomechanical evaluation of the IB technique. Sixteen cadaveric sheep knees underwent monotonic tensile tests, cyclic loading, and passive flexion-extension testing. Data were compared in a series of eight control specimens with an intact ACL and eight repaired specimens where the ACL was cut and repaired using the IB. In parallel with the mechanical testing, finite element analysis (FEA) was performed to investigate the influence of IB loading on the femur-ACL-tibia complex (FATC). The 3D geometry of the FATC was reconstructed from CT scans of the sheep. The IB 3D model was integrated with the 3D FATC for FEA to obtain the femur- repaired ACL with IB - tibia complex (FRA- IB- TC) group. For the intact specimens, the mean (±SD) failure load in the tensile testing was 937 N (±192 N), while for the FRA-IB-TC specimens, it was 519 N (±52 N). The FRA-IB-TC remained biomechanically stable during the cyclic loading testing. The FEA demonstrated an increase in ACL stress to 24.59 MPa and displacement values of 0.391 mm. The IB construct exhibited shear and notch effects at the button-suture-bone fixation site. Testing on this sheep model allowed us a parametric analysis of the impact of the IB repair technique. However, the results will need to be confirmed in a human model. In conclusion, although the IB technique has biomechanical drawbacks, the mechanical properties of the technique are satisfactory.

FEM analysis ; ACL tear ; ACL repair ; Experimental testing

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

95

2021.

76-83

objavljeno

1350-4533

1873-4030

10.1016/j.medengphy.2021.07.013

Povezanost rada

Interdisciplinarne tehničke znanosti

Poveznice
Indeksiranost