Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Adsorption of humic acid from water using chemically modified bituminous coal-based activated carbons (CROSBI ID 297220)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Habuda-Stanić, Mirna ; Tutić, Ana ; Kučić Grgić, Dajana ; Zeko-Pivač, Anđela ; Burilo, Anamarija ; Paixão, Susana ; Teixeira, Veronica ; Pagaimo, Mariana ; Pala, Aysegul ; Ergović Ravančić, Maja et al. Adsorption of humic acid from water using chemically modified bituminous coal-based activated carbons // Chemical and biochemical engineering quarterly, 35 (2021), 2; 189-203. doi: 10.15255/CABEQ.2021.1933

Podaci o odgovornosti

Habuda-Stanić, Mirna ; Tutić, Ana ; Kučić Grgić, Dajana ; Zeko-Pivač, Anđela ; Burilo, Anamarija ; Paixão, Susana ; Teixeira, Veronica ; Pagaimo, Mariana ; Pala, Aysegul ; Ergović Ravančić, Maja ; Šiljeg, Mario

engleski

Adsorption of humic acid from water using chemically modified bituminous coal-based activated carbons

Humic acid (HA) impairs water quality due to its reactivity with many substances present in water. During the drinking-water treatment process and water distribution via water supply system, HA present in water may react with chlorine and other disinfects producing harmful disinfection by-products (DBPs), which are categorized by the International Agency for Research on Cancer (IARC) in groups 2A (probably carcinogenic to humans) or 2B (possibly carcinogenic to humans). Several studies have investigated and reported increased HA removal by iron-coated sorbents. Therefore, the aim of this study was to examine the removal of HA from water by two commercially available bituminous coal-based activated carbons (ACs), Cullar D (Cm) and Hydraffin 30N (Hm). Prior to testing the chosen adsorbents were chemically modified according to two protocols: (1) oxidation by acid mixture (m1), and (2) oxidation with acid mixture followed by iron-ions impregnation (m2). The batch adsorption tests were used to test their efficiency in HA removal under various values of process parameters (initial HA concentration, pH, contact time, adsorbent mass, and temperature). The results showed that up to 96 % of HA removal can be obtained by Cullar D modification Cm1, while maximum uptake of HA by Hydraffin 30N modification was achieved with Hm1 (62.1 %). After surface saturation with Fe3+ –ions (m2), both activated carbons showed similar and lower performances in HA removal (Cm2 up to 66.5 %, and Hm2 up to 50.3 %). FTIR analysis confirmed differences in modified AC structures, as well as favorable structure of Cm1 for HA adsorption.

drinking water ; humic acid ; adsorption ; bituminous coal-based activated carbon ; chemical modification

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

35 (2)

2021.

189-203

objavljeno

0352-9568

1846-5153

10.15255/CABEQ.2021.1933

Povezanost rada

Interdisciplinarne biotehničke znanosti

Poveznice
Indeksiranost