Horizontal UHS Amplitudes for Regions with Deep Soil Atop Deep Geological Sediments—An Example of Osijek, Croatia (CROSBI ID 296521)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Bulajić, Borko Đ. ; Hadzima-Nyarko, Marijana ; Pavić, Gordana Horizontal UHS Amplitudes for Regions with Deep Soil Atop Deep Geological Sediments—An Example of Osijek, Croatia // Applied sciences (Basel), 11 (2021), 14; 6296, 16. doi: 10.3390/app11146296

Podaci o odgovornosti

Bulajić, Borko Đ. ; Hadzima-Nyarko, Marijana ; Pavić, Gordana

engleski

Horizontal UHS Amplitudes for Regions with Deep Soil Atop Deep Geological Sediments—An Example of Osijek, Croatia

In this paper, we demonstrate how UHS-based seismic microzonation can be applied in low-to- medium seismicity areas with deep local soil and deep geological deposits under the local soil. The case study area surrounds the city of Osijek, Croatia, which is in the south–central region of the Pannonian Basin. New frequency- dependent scaling equations are derived, and the empirical response spectra are compared to the spectra of real strong motions in the surrounding region. Empirical calculations for deep soil atop deep geological strata show a 37% reduction in short-period spectral amplitudes when compared to rock locations. This demonstrates that local soil amplification is mitigated by energy dissipation in deep soils. For vibration periods longer than 0.3 s, spectral amplitudes are being amplified. This amplification goes up to 2.37 times for vibration periods around 0.5 s. UHS spectra for Osijek are computed using regional seismicity estimates, data on local soil and deeper geological surroundings, and newly created regional empirical equations for scaling various spectral amplitudes. UHS amplitudes for Osijek are also compared to the Eurocode 8 spectra for ground type C. The results show that ratios of the maximum UHS amplitudes to PGA values are up to 46% larger than the corresponding 2.5 factor that is recommended by Eurocode 8 for horizontal spectra. The UHS results might be viewed as preliminary for Osijek and regions with similar seismicity and local soil and deep geology conditions. When the number of regional strong- motion records grows many times beyond what it is currently, it will be feasible to properly calibrate the scaling equations, resulting in more reliable and long-term UHS estimations for the area under consideration.

UHS ; microzonation ; scaling equations ; deep local soil ; deep geological deposits ; Eurocode 8