Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Investigations into the basic properties of different passive dosimetry systems used in environmental radiation monitoring in the aftermath of a nuclear or radiological event (CROSBI ID 296422)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Knežević, Željka ; Majer, Marija ; Baranowska, Zuzanna ; Ciraj Bjelac, Olivera ; Iurlaro, Giorgia ; Kržanović, Nikola ; Mariotti, Francesca ; Nodilo, Marijana ; Neumaier, Stefan ; Wołoszczuk, Katarzyna et al. Investigations into the basic properties of different passive dosimetry systems used in environmental radiation monitoring in the aftermath of a nuclear or radiological event // Radiation measurements, 146 (2021), 106615, 8. doi: 10.1016/j.radmeas.2021.106615

Podaci o odgovornosti

Knežević, Željka ; Majer, Marija ; Baranowska, Zuzanna ; Ciraj Bjelac, Olivera ; Iurlaro, Giorgia ; Kržanović, Nikola ; Mariotti, Francesca ; Nodilo, Marijana ; Neumaier, Stefan ; Wołoszczuk, Katarzyna ; Živanović, Miloš

engleski

Investigations into the basic properties of different passive dosimetry systems used in environmental radiation monitoring in the aftermath of a nuclear or radiological event

Due to the need for harmonization of passive dosimetry and the requirements of the international standards in the area of environmental monitoring in radiation protection, multiple types of various passive dosimetry systems based on different ionizing radiation detection mechanisms were subjected to extensive performance testing. In the scope of the EMPIR project 16ENV04 Preparedness, the performance of 12 passive dosimetry systems was examined in radiation fields of different photon energies, angles of incidence and ambient dose equivalent rates in order to estimate their performance in the almost omni-directionally and energetically broad radiation field of the natural environment. The use of different detectors, holders, calibrations, measurement procedures and uncertainties, leads to differences in the measured data. Prior investigations and harmonization of passive dosimetry systems are necessary to achieve reliable and comparable dose measurements in Europe

Passive dosimetry systems ; Environmental radiation monitoring ; Nuclear or radiological event

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

146

2021.

106615

8

objavljeno

1350-4487

10.1016/j.radmeas.2021.106615

Trošak objave rada u otvorenom pristupu

Povezanost rada

Fizika, Interdisciplinarne prirodne znanosti, Kemija

Poveznice
Indeksiranost