Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

INHIBITORY EFFECT OF COMMERCIAL INHIBITOR VCI 379/611 ON CORROSION BEHAVIOR OF X153CrMoV12 TOOL STEEL FOR COLD WORK (CROSBI ID 704915)

Prilog sa skupa u zborniku | izvorni znanstveni rad | međunarodna recenzija

Brajčinović, Sandra ; Begić Hadžipašić, Anita ; Kozina, Franjo INHIBITORY EFFECT OF COMMERCIAL INHIBITOR VCI 379/611 ON CORROSION BEHAVIOR OF X153CrMoV12 TOOL STEEL FOR COLD WORK // Proceedings Book of 19th INTERNATIONAL FOUNDRYMEN CONFERENCE Humans - Valuable Resource for Foundry Industry Development / Dolić, Natalija ; Zovko Brodarac, Zdenka ; Brajčinović, Sandra (ur.). Sisak: Metalurški fakultet Sveučilišta u Zagrebu, 2021. str. 260-268

Podaci o odgovornosti

Brajčinović, Sandra ; Begić Hadžipašić, Anita ; Kozina, Franjo

engleski

INHIBITORY EFFECT OF COMMERCIAL INHIBITOR VCI 379/611 ON CORROSION BEHAVIOR OF X153CrMoV12 TOOL STEEL FOR COLD WORK

In this paper, the influence of water and the influence of the commercial inhibitor VCI 379/611 on the corrosion processes of X153CrMoV12 tool steel for cold work were investigated. The research was carried out by electrochemical methods: by measuring the potential of an open circuit, by determining the corrosion parameters using the method of electrochemical impedance spectroscopy (EIS) and method of Tafel extrapolation. After each measurement, the sample surface was analyzed using an optical microscope. The obtained corrosion parameters showed a high efficiency of the applied inhibitor in the protection of tool steels for cold work from corrosion. For the sample that was exposed to distilled water medium with the addition of inhibitor, a significantly lower corrosion rate was registered and no damage to the sample surface was visible. Metallographic images of the electrode surface after polarization measurements in tap water indicate the occurrence of pitting corrosion.

tool steel for cold work, electrochemical techniques, corrosion parameters, inhibitor, microstructure

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

260-268.

2021.

objavljeno

Podaci o matičnoj publikaciji

Dolić, Natalija ; Zovko Brodarac, Zdenka ; Brajčinović, Sandra

Sisak: Metalurški fakultet Sveučilišta u Zagrebu

978-953-7082-39-0

Podaci o skupu

19th International Foundrymen Conference Humans – Valuable Resource for Foundry Industry Development

poster

16.06.2021-18.06.2021

Split, Hrvatska

Povezanost rada

Metalurgija