Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

RENEB/EURADOS Field Exercise 2019: Robust Dose Estimation under outdoor Conditions based on the Dicentric Chromosome Assay (CROSBI ID 295717)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

(RENEB) Endesfelder, David ; Oestreicher, Ursula ; Kulka, Ulrike ; Ainsbury, Elizabeth A. ; Moquet, Jayne ; Barnard, Stephen ; Gregoire, Eric ; Martinez, Juan S. ; Trompier, François ; Ristic, Yoann et al. RENEB/EURADOS Field Exercise 2019: Robust Dose Estimation under outdoor Conditions based on the Dicentric Chromosome Assay // International journal of radiation biology, 97 (2021), 7; 1-48. doi: 10.1080/09553002.2021.1941380

Podaci o odgovornosti

Endesfelder, David ; Oestreicher, Ursula ; Kulka, Ulrike ; Ainsbury, Elizabeth A. ; Moquet, Jayne ; Barnard, Stephen ; Gregoire, Eric ; Martinez, Juan S. ; Trompier, François ; Ristic, Yoann ; Woda, Clemens ; Waldner, Lovisa ; Beinke, Christina ; Vral, Anne ; Barquinero, Joan- Francesc ; Hernandez, Alfredo ; Sommer, Sylwester ; Lumniczky, Katalin ; Hargitai, Rita ; Montoro, Alegría ; Milic, Mirta ; Monteiro Gil, Octávia ; Valente, Marco ; Bobyk, Laure ; Sevriukova, Olga ; Sabatier, Laure ; Prieto, María Jesús ; Moreno Domene, Mercedes ; Testa, Antonella ; Patrono, Clarice ; Terzoudi, Georgia ; Triantopoulou, Sotiria ; Histova, Rositsa ; Wojcik, Andrzej

RENEB

engleski

RENEB/EURADOS Field Exercise 2019: Robust Dose Estimation under outdoor Conditions based on the Dicentric Chromosome Assay

Purpose: Depending on the exposure scenario, different biological and/or physical assays will be required to recover the exposure situation and to obtain reliable dose estimates to aid medical decision making. Inter-laboratory comparisons (ILCs) are a central tool to validate and improve the performance of methods and laboratories. In most cases such ILCs are performed under laboratory conditions where the influence of parameters contributing to uncertainties can be minimized. In a reallife scenario, the situation is much more complicated, and it is therefore crucial to validate methods and laboratories’ abilities to carry out these methods under more realistic conditions. In 2019, EURADOS (The European Radiation Dosimetry Group) Working Group 10 (Retrospective Dosimetry) and RENEB (Running the European Network of Biological and retrospective Physical dosimetry) organized a field exercise in Lund, Sweden, to validate different methods for biological and physical retrospective dosimetry in parallel by simulating real- life exposure scenarios. Materials and methods: For the dicentric chromosome assay (DCA), 18 blood tubes were distributed across 8 thermos flasks filled with heated water and positioned at the hips and shoulders of anthropomorphic phantoms in different geometries. Two irradiations were performed with a 1.36 TBq 192Ir-source, each with two phantoms, to simulate close, distant, lateral or partially shielded exposures. For each of the blood tubes DCA dose estimates were provided by at least one laboratory and for tubes from four thermos flasks by 17 participating RENEB laboratories. In addition, blood from the different thermos flasks on each phantom was mixed to simulate heterogeneous exposures. Three radio-photoluminescence (RPL) glass dosimeters (GD) were placed at each tube to assess reference doses and the inter- and intra-tube variability. Results: The results from the DCA were homogeneous between participants and matched well with RPL GD reference doses (≥95% of estimates within ±0.5 Gy of the reference). For samples close to the source, exposed to doses >1 Gy, systematic underestimation could be corrected by accounting for exposure time. Heterogeneity within and between tubes was detected for RPL GD reference doses as well as for doses estimates from the DCA. The sample simulating a heterogeneous exposure with two different doses was detected by ~50% of the participants. Conclusions: The participants were able to successfully estimate the doses and to provide important information on the exposure scenarios under conditions closely resembling a real-life situation. The reliability of the results emphasizes the value of the DCA for retrospective dosimetry under field conditions.

dicentric chromosome, RENEB, EURADOS, inter-laboratory comparison, biological dosimetry

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

97 (7)

2021.

1-48

objavljeno

0955-3002

10.1080/09553002.2021.1941380

Povezanost rada

Biologija, Biotehnologija u biomedicini (prirodno područje, biomedicina i zdravstvo, biotehničko područje), Biotehnologija, Dentalna medicina, Interdisciplinarne biotehničke znanosti

Poveznice
Indeksiranost