Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Overestimation of 3α- over 3β-25-Hydroxyvitamin D3 Levels in Serum: A Mechanistic Rationale for the Different Mass Spectral Properties of the Vitamin D Epimers (CROSBI ID 293355)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Schorr, Pascal ; Kovačević, Borislav ; Volmer, Dietrich A. Overestimation of 3α- over 3β-25-Hydroxyvitamin D3 Levels in Serum: A Mechanistic Rationale for the Different Mass Spectral Properties of the Vitamin D Epimers // Journal of the American Society for Mass Spectrometry, 32 (2021), 4; 1116-1125. doi: 10.1021/jasms.1c00054

Podaci o odgovornosti

Schorr, Pascal ; Kovačević, Borislav ; Volmer, Dietrich A.

engleski

Overestimation of 3α- over 3β-25-Hydroxyvitamin D3 Levels in Serum: A Mechanistic Rationale for the Different Mass Spectral Properties of the Vitamin D Epimers

The metabolism of vitamin D3 includes a parallel C-3 epimerization pathway—in addition to the standard metabolic processes for vitamin D3— reversing the stereochemical configuration of the −OH group at carbon-3 (β→α). While the biological function of the 3α epimer has not been elucidated yet, the additional species cannot be neglected in the analytical determination of vitamin D3, as it has the potential to introduce analytical errors if not properly accounted for. Recently, some inconsistent mass spectral behavior was seen for the 25-hydroxyvitamin D3 (25(OH)D3) epimers during quantification using electrospray LC–MS/MS. The present work extends that of Flynn et al. ( Ann. Clin. Biochem. 2014, 51, 352−559) and van den Ouweland et al. ( J. Chromatogr. B 2014, 967, 195−202), who reported larger electrospray ionization response factors for the 3α epimer of 25(OH)D3 in human serum samples as compared to the regular 3β variant. The present work was concerned with the mechanistic reasons for these differences. We used a combination of electrospray ionization, atmospheric pressure chemical ionization, and density functional theory calculations to uncover structural dissimilarities between the epimers. A plausible mechanism is described based on intramolecular hydrogen bonding in the gas phase, which creates a small difference of proton affinities between the epimers. More importantly, this mechanism allows the explanation of the different ionization efficiencies of the epimers based on kinetic control of the ionization process, where ionization initially takes place at the hydroxyl group with subsequent proton transfer to a basic carbon atom. The barrier for this transfer differs between the epimers and is in direct competition with H2O elimination from the protonated hydroxyl group. The “hidden” site of high gas phase basicity was revealed through computational calculations and appears to be inaccessible via direct protonation.

vitamin D3 ; epimers ; LC−MS/MS ; response factor ; electrospray ionization ; computational calculations

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

32 (4)

2021.

1116-1125

objavljeno

1044-0305

1879-1123

10.1021/jasms.1c00054

Povezanost rada

Kemija

Poveznice
Indeksiranost