Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Seismic designs of some recent bridges created by the structural department of Zagreb Faculty of civil engineering (CROSBI ID 701856)

Prilog sa skupa u zborniku | izvorni znanstveni rad | međunarodna recenzija

Šavor, Zlatko ; Mujkanović, Nijaz ; Hrelja Kovačević, Gordana ; Vlašić, Anđelko ; Srbić, Mladen Seismic designs of some recent bridges created by the structural department of Zagreb Faculty of civil engineering // 1st Croatian Conference on Earthquake Engineering - 1CroCEE / Lakušić, Stjepan ; Atalić, Josip (ur.). Zagreb, 2021. str. 1165-1175

Podaci o odgovornosti

Šavor, Zlatko ; Mujkanović, Nijaz ; Hrelja Kovačević, Gordana ; Vlašić, Anđelko ; Srbić, Mladen

engleski

Seismic designs of some recent bridges created by the structural department of Zagreb Faculty of civil engineering

Over the last 20 years, beside their primary educational activities, members of the Bridge Chair of the Zagreb Faculty of Civil Engineering Structural Department also worked professionally on main and execution designs of many bridges. Most of them are mid-span to large span bridges, requiring detailed seismic design, especially since their locations are predominantly in highly seismic active regions. These bridges were designed during the transition period from old seismic standards, to ENV pre-standards, and finally to EC8 standards. The evolution of these codes had a great impact on the design. New demands in terms of seismic behaviour influenced all aspects of design, from conceptual design (structural system and material options), sizing of elements, foundation type, bearing and damper layouts, special equipment selection, erection details, to maintenance requirements. An overview of seismic design requirements, solutions, and peculiarities for each of these bridges, which were recently constructed or are currently under construction, is presented in the paper. Since the design of the cable stayed bridge Franjo Tuđman in Dubrovnik, where fluid viscous dampers were first employed in Croatia, to the recent bridge designs, various approaches were utilized to mitigate and take over the seismic actions. Adequate solutions were found either by structural detailing and/or by installation of seismic isolators, depending on bridge structural systems, utilized materials, but also on the characteristics of foundation soil.

bridges, seismic design, seismic behaviour, Eurocode, seismic isolators, structural detailing

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

1165-1175.

2021.

objavljeno

Podaci o matičnoj publikaciji

1st Croatian Conference on Earthquake Engineering - 1CroCEE

Lakušić, Stjepan ; Atalić, Josip

Zagreb:

978-953-8168-47-5

Podaci o skupu

1st Croatian Conference on Earthquake Engineering (1CroCEE)

predavanje

22.03.2021-24.03.2021

Zagreb, Hrvatska

Povezanost rada