Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

Viable Environmental Monitoring (EM) of ATMP Production Facility at Tissue Bank, UHC Sestre milosrdnice Zagreb, Croatia (CROSBI ID 701570)

Prilog sa skupa u zborniku | sažetak izlaganja sa skupa | međunarodna recenzija

Vrgoc, Ivana ; Bujic, Marina ; Dolenec, Tamara ; Zmis, Goradana ; Jevak, Martina ; Tominac Trcin, Mirna ; Batarilo, Ivanka Viable Environmental Monitoring (EM) of ATMP Production Facility at Tissue Bank, UHC Sestre milosrdnice Zagreb, Croatia. 2015. str. ---

Podaci o odgovornosti

Vrgoc, Ivana ; Bujic, Marina ; Dolenec, Tamara ; Zmis, Goradana ; Jevak, Martina ; Tominac Trcin, Mirna ; Batarilo, Ivanka

engleski

Viable Environmental Monitoring (EM) of ATMP Production Facility at Tissue Bank, UHC Sestre milosrdnice Zagreb, Croatia

Viable Environmental Monitoring (EM) for an ATMP aseptic manufacturing area includes personnel, air and area surfaces control for the presence of microorganisms. Qualification studies and written procedures should exist for the selection of sampling sites, frequencies and modes of microbial testing. For a given class of air cleanness alert and action levels must be predetermined. Microbiological sampling of our personnel, surfaces and the air was carried out using contact and settle plates and active sampling device. Frequencies’ of microbial testing depended on cleanroom category and for A and B class included each working session. Number of sampling locations per room was calculated from square root of cleanroom zone area in m2. Last year we had in A class: 0.6 % of action levels for both, the air and surface testing. B class showed: 5% alerts and 4% action levels for the air samples and 1% of alerts and action levels for surface testing. 8 bacterial and fungal species were isolated from different room areas. The most detected microorganism in A and B (air -39% ; surface -55%), C (air-35% ; surface-48%) and surface of D class (69%) was CoNS. In the air of D class most detected microorganism was Micrococcus spp. (39%). We have determined the microbial distribution in our cleanroom facility. Several bacterial species were identified as the most probable contaminants that could affect our final product – cultivated epithelial autografts (CEA). Knowing the EM data and undertaking appropriate corrective measures the risk of contamination can be significantly reduced.

cleanroom ; ATMP ; microbiological sampling ; personnel ; air and area surface ; microbiological detection

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

---.

2015.

objavljeno

Podaci o matičnoj publikaciji

Podaci o skupu

25th Congress of European Association of Tissue Banks

poster

01.10.2015-03.10.2015

Split, Hrvatska

Povezanost rada

Biologija, Biotehnologija u biomedicini (prirodno područje, biomedicina i zdravstvo, biotehničko područje), Interdisciplinarne biotehničke znanosti