Salty Crackers as Fortuitous Dosimeters: A Novel PSL Method for Rapid Radiation Triage (CROSBI ID 292501)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Maltar-Strmečki, Nadica ; Vidotto, Monica ; Della Monaca, Sara ; Erceg, Ina ; Fattibene, Paola ; Vojnić Kortmiš, Maja ; Quattrini, Maria Cristina ; Bortolin, Emanuela Salty Crackers as Fortuitous Dosimeters: A Novel PSL Method for Rapid Radiation Triage // Frontiers in public health, 9 (2021), 661376, 6. doi: 10.3389/fpubh.2021.661376

Podaci o odgovornosti

Maltar-Strmečki, Nadica ; Vidotto, Monica ; Della Monaca, Sara ; Erceg, Ina ; Fattibene, Paola ; Vojnić Kortmiš, Maja ; Quattrini, Maria Cristina ; Bortolin, Emanuela

engleski

Salty Crackers as Fortuitous Dosimeters: A Novel PSL Method for Rapid Radiation Triage

When a radiological and nuclear (R/N) emergency occurs, the categorization of Q17 individuals into those who are unaffected and those requiring medical intervention is a high priority. At times, a professional dosimeter is not available and therefore some common belongings may be used as fortuitous dosimeters. The preparation of these objects for the measurement should be such as to give the most accurate and precise results. This paper focused on the Photo- Stimulated Luminescence (PSL) response of salty crackers confronts the problem of sample preparation (mass, grain size), dose response and signal stability. The dose response was determined for doses up to 5Gy, which allowed the calculation of the limit of detection. Additionally, the signal stability was investigated for samples irradiated with 0.3 and 3Gy. The observed decrease of the signal does not prevent the detection in the dose range typical for R/N emergency. The main dosimetric characteristics were investigated by using two different models of PSL readers equipped with single (infrared) or double (infrared, blue light) stimulation. The results indicated that the limit of detection can be improved by applying blue light stimulation. Moreover, strong correlation of the measurements performed in the two different instrument, as well as the rapidity of the analysis and the simplicity of the operations, suggest that this method can be suitable for a rapid radiation triage of a large number of civilians in amass casualty event. The study was simultaneously conducted by two laboratories (Ruder Boškovic´ Institute, RBI, Croatia and Istituto Superiore di Sanità, ISS, Italy) involved in the BioPhyMeTRE project (grant No. G5684) supported by NATO Science for Peace and Security Programme.

retrospective dosimetry ; fortuitous dosimeters ; photo-stimulated luminescence ; radiation triage ; salty snacks